Abilities of Pulse Pressure Variations and Stroke Volume Variations to Predict Fluid Responsiveness in Prone Position During Scoliosis Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
2
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 8 publications
1
11
2
2
Order By: Relevance
“…25 Systolic pressure variation may also be used for fluid status monitoring as it increases during hypovolemia. 27 High-risk patients should be identified so that positioning can be optimized, and adhesive defibrillator pads can be applied prior to surgery.…”
Section: Recommendationsmentioning
confidence: 99%
“…25 Systolic pressure variation may also be used for fluid status monitoring as it increases during hypovolemia. 27 High-risk patients should be identified so that positioning can be optimized, and adhesive defibrillator pads can be applied prior to surgery.…”
Section: Recommendationsmentioning
confidence: 99%
“…Les dispositifs de monitorage non invasif du débit cardiaque qui se fondent sur le débit systolique ou sur la variation de la pression différentielle ont été validés pour prédire la réponse au remplissage en position ventrale. 20 Quant à l'ETO en position ventrale, son utilité est diminuée par les mouvements restreints de la sonde et les fenêtres échocardiographiques limitées, ainsi que par des inquiétudes reliées au risque de lésions de la langue et du pharynx lors d'interventions prolongées. Il pourrait être extrêmement difficile d'insérer une sonde d'ETO après le positionnement du patient en position ventrale, particulièrement si sa tête est maintenue dans un clameau crânien Mayfield.…”
Section: Induction / Prise En Charge Des Voies Aériennesunclassified
“…Noninvasive cardiac output monitoring devices based on stroke volume or pulse pressure variation have been validated to predict fluid responsiveness in the prone position. 20 The use of TEE in the prone position has been hindered by limited probe movement and echocardiographic views, as well as cumbersome ergonomics, and concerns about tongue and oropharyngeal pressure injuries in prolonged procedures. It may be extremely difficult to insert a TEE probe after the patient has been turned into the prone position, especially if the head is fixed in a Mayfield clamp.…”
Section: Hemodynamic Managementmentioning
confidence: 99%
“…El paciente quirúrgico puede precisar fluidos para corregir diversas situaciones clínicas: restauración de la volemia ante pérdidas hemáticas; fluidoterapia de mantenimiento después de la cirugía; pérdidas que se producen por los tractos gastrointestinal o urinario, o pérdidas insensibles elevadas por fiebre y quemaduras 5 ; la redistribución de fluidos puede desarrollar edema tisular por exceso de agua y sodio y puede haber secuestro de líquido en el tracto gastrointestinal o en la cavidad torácica y/o peritoneal 18 . Además, en el paciente quirúrgico pueden presentarse cambios hemodinámicos inducidos por la anestesia, como la vasoparesia y venodilatación en respuesta a bloqueo neuroaxial 19 y cambios hemodinámicos inducidos por factores quirúrgicos, como son la colocación del paciente 20 o la aplicación de presión en cavidades corporales, como en el neumoperitoneo, para facilitar la cirugía laparoscópica, que inducen una situación de déficit funcional de volumen.…”
Section: Fluidoterapia Perioperatoriaunclassified