Absolute Analysis of Particulate Materials by Laser-Induced Breakdown Spectroscopy

Abstract: We have developed a new data acquisition approach followed by a suitable data analysis for Laser-induced breakdown spectroscopy. It provides absolute concentrations of elements in particulate materials (e.g., industrial dusts and soils). In contrast to the known calibration procedures (based on the ratio of spectral lines), which are applicable only when one component is constant, this approach requires no constant constituent and results in absolute (rather than relative) concentrations. Thus, the major drawb… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
87
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
6
2
2

Relationship

1
9

Authors

Journals

citations
Cited by 121 publications
(88 citation statements)
references
References 25 publications
1
87
0
Order By: Relevance
“…Reference sample (sample number S9255, produced by Central Iron and Steel Institute) was analyzed by line scan mode using LIBS and EPMA, the result showed that relative standard deviation (RSD) of chemical content for Si, Mn, Cr, Cu was However, LIBS precision could be improved using a normalization procedure 20) and absolute analyses for particulate material. 21) …”
Section: Comparing Precision and Accuracy For Libs Andmentioning
confidence: 99%
“…Reference sample (sample number S9255, produced by Central Iron and Steel Institute) was analyzed by line scan mode using LIBS and EPMA, the result showed that relative standard deviation (RSD) of chemical content for Si, Mn, Cr, Cu was However, LIBS precision could be improved using a normalization procedure 20) and absolute analyses for particulate material. 21) …”
Section: Comparing Precision and Accuracy For Libs Andmentioning
confidence: 99%
“…Recently, a method to correlate the LIBS signal with continuum background to correct the LIBS signal variation, due to the laser shot-to-shot fluctuations and laser-matter interaction, has been receiving a lot of attention. 15,16 We also conducted a series of studies to correlate the LIBS background with changes in excitation conditions. A linear relationship between the LIBS calibration slope and background for Cd and Be was found.…”
Section: Calibrationmentioning
confidence: 99%
“…These include biomedical applications, plasma-mediated eye and biological tissues surgery [1,2], selective cell targeting with light-absorbing nanoparticles, chemical engineering and generation of micro/nano-particles. It is also relevant to numerous analytical applications based on laser plasma spectroscopy [3][4][5][6].…”
Section: Introductionmentioning