1992
DOI: 10.1016/0041-624x(92)90041-j
|View full text |Cite
|
Sign up to set email alerts
|

Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

8
294
0
2

Year Published

1993
1993
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 459 publications
(304 citation statements)
references
References 9 publications
8
294
0
2
Order By: Relevance
“…34,35 Microbubbles can have vibrational resonance at very specific frequencies, as seen with sonographic contrast agents, but their resonance does not cause the artifacts that are seen in lung scans, and they in fact behave like Rayleigh scatterers. 36 If this were true, in fact, ring-down artifacts would also be seen when bubble contrast agents are introduced into the bloodstream. On the contrary, bubbles with a large radius, above the threshold of an oscillating system, act as specular reflectors and, if large, create transducer (horizontal) reverberations.…”
Section: Discussionmentioning
confidence: 99%
“…34,35 Microbubbles can have vibrational resonance at very specific frequencies, as seen with sonographic contrast agents, but their resonance does not cause the artifacts that are seen in lung scans, and they in fact behave like Rayleigh scatterers. 36 If this were true, in fact, ring-down artifacts would also be seen when bubble contrast agents are introduced into the bloodstream. On the contrary, bubbles with a large radius, above the threshold of an oscillating system, act as specular reflectors and, if large, create transducer (horizontal) reverberations.…”
Section: Discussionmentioning
confidence: 99%
“…Non-linear contacts [6,7], forcechains [8], frequency-dependence [9,10] and also scattering and attenuation in other "particle type" materials [11] are reported. Ballistic pulse propagation can co-exist with a slower multiply scattered, coda-like signal [4,12], and the stress-and frequency-dependence of the wave propagation features are subject of ongoing discussion [3,4] in static and shaken packings as well.…”
Section: Introductionmentioning
confidence: 95%
“…De Jong et al (1992) have shown that this degree of attenuation is apparent for Albunex ® when diluted l:10,000. In the worst case, the 2.5 mL injectate diluted in the blood volume of the human (5 L) gives a dilution of 1:2,000.…”
Section: Discussionmentioning
confidence: 98%
“…8. The bar diagram gives the normalized number of counts as function of the channel diameter as measured with a Coulter Multisizer II (De Jong et al 1992). The Multisizer has an aperture of 50 tim employing 64 channels with diameters ranging from 1 to 35 #m. The width of each channel increases for larger channel diameters as indicated in the figure.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation