2013 7th IEEE GCC Conference and Exhibition (GCC) 2013
DOI: 10.1109/ieeegcc.2013.6705820
|View full text |Cite
|
Sign up to set email alerts
|

AC solid state circuit breakers for fault current limitation in distributed generation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…Various approaches and methods have been developed for the implementation of solid state protection so that operation can be accomplished safely, quickly, at a lower cost and loss with increased long-term dependability interruption fault current switching [38,[41][42][43][44][45][46][47][48][49]. Prototyping for interruption of faults has recently been completed and experimentally demonstrated the presence of interruptions [46,[50][51][52][53][54][55][56][57][58]. The overall survey found that the feasibility of maintaining high levels of selectivity and quick fault detection by using a variety of security methods was proven.…”
Section: Publication Trends and Citation Structuresmentioning
confidence: 99%
“…Various approaches and methods have been developed for the implementation of solid state protection so that operation can be accomplished safely, quickly, at a lower cost and loss with increased long-term dependability interruption fault current switching [38,[41][42][43][44][45][46][47][48][49]. Prototyping for interruption of faults has recently been completed and experimentally demonstrated the presence of interruptions [46,[50][51][52][53][54][55][56][57][58]. The overall survey found that the feasibility of maintaining high levels of selectivity and quick fault detection by using a variety of security methods was proven.…”
Section: Publication Trends and Citation Structuresmentioning
confidence: 99%
“…In addition, high-speed circuit breakers operating with high rated currents are bulky and expensive equipment. With the development of high power semiconductor technology, prerequisites have been created for the development of non-contact high-speed switches [21] - [23]. These devices provide operation without arcing, as there are no moving contact parts and there is no wear and tear that occurs when switching classic circuit breakers.…”
Section: Achievements and Publications Analysismentioning
confidence: 99%
“…In recent times, power semiconductors have been used to substitute MCBs. These kinds of configurations are called solid-state circuit breaker (SSCB) [1][2][3][4]. There is no arcing, no contact erosion, so that the lifetime of an SSCB is high than an MCB.…”
Section: Introductionmentioning
confidence: 99%