2020
DOI: 10.1186/s42444-020-00020-w
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and clinical feasibility of 3D-myocardial thickness map measured by cardiac computed tomogram

Abstract: Background: Although myocardial thickness is an important variable for therapeutic catheter ablation of cardiac arrhythmias, quantification of wall thickness has been overlooked. We developed a software (AMBER) that measures 3D-myocardial thickness using a cardiac computed tomogram (CT) image, verified its accuracy, and tested its clinical feasibility. Methods: We generated 3D-thickness maps by calculating wall thickness (WT) from the CT images of 120 patients' hearts and a 3D-phantom model (PhM). The initial … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 10 publications
(16 citation statements)
references
References 34 publications
0
16
0
Order By: Relevance
“…We developed a customized software (AMBER, Laonmed Inc., Seoul, Korea) that measured the LA wall thickness by applying Laplace's equation in the cardiac CT images (Kwon et al, 2020 ; Lee et al, 2021b ). The CT scan was conducted within a month before the AFCA.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…We developed a customized software (AMBER, Laonmed Inc., Seoul, Korea) that measured the LA wall thickness by applying Laplace's equation in the cardiac CT images (Kwon et al, 2020 ; Lee et al, 2021b ). The CT scan was conducted within a month before the AFCA.…”
Section: Methodsmentioning
confidence: 99%
“…The spatial resolution of the CT was set to the normalized vector in the 3D Euclidean space. The methods and principles of the customized software (AMBER) were previously described in detail, and the results have been well validated with a 3D printed phantom model in 120 patients (Kwon et al, 2020 ; Lee et al, 2021b ). In brief, the endocardium of the LA was semiautomatically divided on the cardiac CT using an edge detector.…”
Section: Methodsmentioning
confidence: 99%
“…AF, atrial fibrillation; AFCA, atrial fibrillation catheter ablation; AI, artificial intelligence; LAW-stress, left atrial wall stress. (Kwon O. S. et al, 2020;Lee et al, 2021). The number of rows and columns of CT image pixels were 512, and the number of slices was approximately 320 at the z-axis.…”
Section: Electrophysiological Studies and Afcamentioning
confidence: 99%
“…The spatial resolution of CT was set to the normalized vector in 3D Euclidean space. The methods and principles of the customized software (AMBER) were previously described in detail, and the results have been well validated with a 3D printed phantom and in 120 patients (Kwon O. S. et al, 2020;Lee et al, 2021). In brief, the endocardium of the LA was semi-automatically divided on the cardiac CT by using the edge detector.…”
Section: Electrophysiological Studies and Afcamentioning
confidence: 99%
See 1 more Smart Citation