2015
DOI: 10.4041/kjod.2015.45.3.105
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system

Abstract: ObjectiveA recently developed facial scanning method uses three-dimensional (3D) surface imaging with a light-emitting diode. Such scanning enables surface data to be captured in high-resolution color and at relatively fast speeds. The purpose of this study was to evaluate the accuracy and precision of 3D images obtained using the Morpheus 3D® scanner (Morpheus Co., Seoul, Korea).MethodsThe sample comprised 30 subjects aged 24-34 years (mean 29.0 ± 2.5 years). To test the correlation between direct and 3D imag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
38
1
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(42 citation statements)
references
References 13 publications
1
38
1
2
Order By: Relevance
“…All subjects underwent clinical evaluations conducted by the investigators, as well as photographic and Morpheus 3D ® (Morpheus Co., Ltd., Seong-nam, Korea) scanning evaluations, at baseline and at 30 min, 3 days and 2, 4, 12, and 24 weeks after procedural completion. The Morpheus 3D ® system is a 3D photogrammetry imaging device based on a structured light scanning system, and the accuracy and reproducibility of the obtained results have been reported previously (Kim et al, 2015).…”
Section: Methodsmentioning
confidence: 86%
“…All subjects underwent clinical evaluations conducted by the investigators, as well as photographic and Morpheus 3D ® (Morpheus Co., Ltd., Seong-nam, Korea) scanning evaluations, at baseline and at 30 min, 3 days and 2, 4, 12, and 24 weeks after procedural completion. The Morpheus 3D ® system is a 3D photogrammetry imaging device based on a structured light scanning system, and the accuracy and reproducibility of the obtained results have been reported previously (Kim et al, 2015).…”
Section: Methodsmentioning
confidence: 86%
“…We previously introduced a basic concept of objective approach to evaluate skin conditions . Optical profilometry is one of the practical methods for analyzing the skin surface, and three‐dimensional scanners were recently reported to be useful for assessing facial integumental data . However, the scanners are still expensive and occupy much space.…”
Section: Discussionmentioning
confidence: 99%
“…20 Optical profilometry is one of the practical methods for analyzing the skin surface, 21 and three-dimensional scanners were recently reported to be useful for assessing facial integumental data. [22][23][24] However, the scanners are still expensive and occupy much space. Linear gray scale analysis was proved to be a potent objective substitute with high reliability for conventional subjective wrinkle rating system.…”
Section: Discussionmentioning
confidence: 99%
“…Recent researchers suggest that 3-D facial scanning is sufficiently accurate for clinical use, but they also suggest that distortion of the paranasal or submandibular areas due to different head postures may occur when this modality is used due to its inherent overlapping image-combining system, which is based on three captures (anterior, right, and left). 12,13 However, there is much evidence that CBCT analysis guarantees the accuracy and reliability of evaluating facial hard and soft tissue a Wilcoxon rank sum test between pretreatment and posttreatment. Significant values mean that the measurements showed statistical differences between pretreatment and posttreatment.…”
Section: Discussionmentioning
confidence: 99%