2019
DOI: 10.1016/j.oooo.2018.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and reliability of mandibular digital model registration with use of the mucogingival junction as the reference

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
38
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(40 citation statements)
references
References 26 publications
2
38
0
Order By: Relevance
“…Previous studies described an excellent reproducibility for digital measurements in DDM and CBCT. 10,20,27,[31][32][33][34] The results from this present study confirm those findings for 3D dental linear displacements with similar values for DDM and CBCT methods, as measured at the mesiobuccal cusp of the first molars, canine tip and incisal surface of the incisors.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…Previous studies described an excellent reproducibility for digital measurements in DDM and CBCT. 10,20,27,[31][32][33][34] The results from this present study confirm those findings for 3D dental linear displacements with similar values for DDM and CBCT methods, as measured at the mesiobuccal cusp of the first molars, canine tip and incisal surface of the incisors.…”
Section: Discussionsupporting
confidence: 89%
“…For the approximation step, mesiobuccal cusp of second molar, buccal cusp of the second premolar and canine tip on the left and right sides were used. 27 The registration was performed using landmarks at the centre of the buccal surface of all teeth in both CBCT and digital dental models at T1 27 ;…”
mentioning
confidence: 99%
“…As the width of keratinized gingiva reflects the position of the mucogingival junction, the result indicated that even in mild periodontitis, inflammation can affect soft tissue beyond the mucogingival junction, particularly in sextants with greater PD than KW, which accounted for approximately 37.0% of all sextants. The mucogingival junction remains stable even if the gingiva is apically repositioned [34], and using it as an alignment reference has been confirmed to be reliable [35]. The current result showed that "stable" means a relative constant position in the coronal-apical direction, rather than in the buccal-lingual direction.…”
Section: Discussionsupporting
confidence: 56%
“…Reference best fit alignment produced significantly lower alignment errors and truer measurements [18]. Thus, the greatest challenge in aligning digital models of different models or different time points is to identify a stable structure that can be used as a reference [24]. Teeth could be used as such a reference given the lack of mobility in Group H, and mobility less than I° before and after treatments in Group P [25,26].…”
Section: Discussionmentioning
confidence: 99%
“…2021, 11, x FOR PEER REVIEW 10 of 13 also be used in dental offices in combination with 3D data to the CBCT and the patients (Figure 4). The superimposition of CBCT and digital motion scans can be achieved by the use of the mucogingival junction as a reference as described by Ioshida et al [31]. The visualization of the movement of the craniofacial structures avoids the necessity of performing more complicate and expensive exams as dynamic RMI and could offer a new The superimposition of CBCT and digital motion scans can be achieved by the use of the mucogingival junction as a reference as described by Ioshida et al [31].…”
Section: Discussionmentioning
confidence: 99%