2019
DOI: 10.1016/j.arth.2019.06.040
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of a New Robotically Assisted Technique for Total Knee Arthroplasty: A Cadaveric Study

Abstract: Background: Although the utility of robotic surgery has already been proven in cadaveric studies, it is our hypothesis that this newly designed robotically assisted system will achieve a high level of accuracy for bone resection. Therefore, we aimed to analyze in a cadaveric study the accuracy to achieve targeted angles and resection thickness. Methods: For this study, 15 frozen cadaveric specimens (30 knees) were used. In this study, Zimmer Biomet (Warsaw, IN) knees, navigation system, and robot (ROSA Knee Sy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
85
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 113 publications
(88 citation statements)
references
References 15 publications
1
85
0
2
Order By: Relevance
“…In order to achieve these goals, the robotic arm assists in positioning the cutting jigs in the appropriate planned cutting plane. In cadaveric studies, this robotic system has demonstrated 100% accuracy to within 3 degrees of goal for tibial and femoral coronal angles, tibial slope, and the hip-knee-ankle angle [18]. Additionally, that study demonstrated planned resections to be within 2 mm of goal in >90% of the specimens reviewed.…”
Section: Discussionmentioning
confidence: 83%
See 2 more Smart Citations
“…In order to achieve these goals, the robotic arm assists in positioning the cutting jigs in the appropriate planned cutting plane. In cadaveric studies, this robotic system has demonstrated 100% accuracy to within 3 degrees of goal for tibial and femoral coronal angles, tibial slope, and the hip-knee-ankle angle [18]. Additionally, that study demonstrated planned resections to be within 2 mm of goal in >90% of the specimens reviewed.…”
Section: Discussionmentioning
confidence: 83%
“…This enables the robot to identify the knee in space and allows the surgeon to make real-time intraoperative, patient-specific adjustments according to the patient's unique anatomy. The robotic arm assists in positioning the cutting jigs in the planned cutting plane and allows for accuracy down to 0.5 mm [7,18].…”
Section: Case Presentationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding the radiological findings, lower incidence of outliers was assessed for mechanical axis (θ), coronal (a) and sagittal (g) femoral inclinations and coronal (b) and sagittal (d) tibial inclinations confirming the higher accuracy and precision of the technique. The high degree of accuracy was demonstrated in the cadaveric study by Parratte et al , 19 using the Rosa Knee System (Zimmer-Biomet, Warsaw, Indiana, USA). The author reported no significant difference compared to the preoperative plan in resection angles (except for the femoral flexion angle, mean difference of -0.95°); no differences regarding the thickness of the resection (except for the distal medial femoral and medial proximal tibial cuts) and the hip-knee-ankle angle mean difference was -0.03°±0.87°.…”
Section: Discussionmentioning
confidence: 92%
“…cobot), while the surgeon performs the bone cuts. 19 Conversely, the Navio Surgical System and the Mako Robotic Arm Interactive Orthopaedic system do not require cutting blocks but creates stereotactic boundaries that assist the surgeon in the tibial and femoral resections.…”
Section: Introductionmentioning
confidence: 99%