Accuracy of an Automated Blood Pressure Device in Stable Inpatients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(28 citation statements)
references
References 13 publications
0
28
0
Order By: Relevance
“…The former conclusion was reached since the tested device did not satisfy the requirements of the AAMI and the BHS standards. Alternatively, the possibility that mercury sphygmomanometry-the gold standard with which automatic devices are compared 4 -was inaccurate has been excluded since differences between manual measurements by blinded and trained observers were insignificant.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The former conclusion was reached since the tested device did not satisfy the requirements of the AAMI and the BHS standards. Alternatively, the possibility that mercury sphygmomanometry-the gold standard with which automatic devices are compared 4 -was inaccurate has been excluded since differences between manual measurements by blinded and trained observers were insignificant.…”
Section: Discussionmentioning
confidence: 99%
“…The total number of BP measurements for both the READ and for validation studies is comparable, and covers the spectrum of low, medium and high BP in similar proportions for both methods. 2,4,9 Since discrepancies between automatic devices and the mercury standard are influenced by age, 10 subjects covering a spectrum of ages from 23 to 74 years were chosen for the READ.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…20 A mercury column sphygmomanometer (Baumanometer, standby model 0661-0250) was utilized for measurement of the BP, since this is the standard method to which other noninvasive devices of BP measurement are validated. 21 Studies on the accuracy of automated BP measurement devices showed that the majority of measurements overestimated the DBP, the SBP error varied with the device 22 and there was no predictable aberration pattern of the automated measurements. 23 The HR was recorded on an electrocardiographic monitor.…”
Section: Protocol Of the Capnography-hutt 19mentioning
confidence: 99%
“…ation of BP at rest 12,13 and during HUTT. 14,15 The HR measurements were recorded on an electrocardiographic monitor.…”
Section: Study Populationmentioning
confidence: 99%