2014
DOI: 10.1016/j.cgh.2013.12.027
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Capsule Colonoscopy and Computed Tomographic Colonography in Individuals With Positive Results From the Fecal Occult Blood Test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
69
2
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 75 publications
(77 citation statements)
references
References 13 publications
4
69
2
2
Order By: Relevance
“…All four cases of CRC were detected by the capsule. A recent study compared colon capsule endoscopy using the PillCam2 capsule to CT colonography to preselect individuals with positive fecal occult blood test to optical colonoscopy by identifying those with at least one polyp greater than 6 mm [8]. They found that both methods detect the polyps in 16 of 50 cases with high level of accuracy: sensitivity of the capsule was 88 %, specificity 88 %, and PLR of 3.75 and NLR of 0.06.…”
Section: Surveillancementioning
confidence: 94%
See 1 more Smart Citation
“…All four cases of CRC were detected by the capsule. A recent study compared colon capsule endoscopy using the PillCam2 capsule to CT colonography to preselect individuals with positive fecal occult blood test to optical colonoscopy by identifying those with at least one polyp greater than 6 mm [8]. They found that both methods detect the polyps in 16 of 50 cases with high level of accuracy: sensitivity of the capsule was 88 %, specificity 88 %, and PLR of 3.75 and NLR of 0.06.…”
Section: Surveillancementioning
confidence: 94%
“…They found that both methods detect the polyps in 16 of 50 cases with high level of accuracy: sensitivity of the capsule was 88 %, specificity 88 %, and PLR of 3.75 and NLR of 0.06. Most subjects preferred the capsule exam to the CT colonography [8].…”
Section: Surveillancementioning
confidence: 99%
“…This time and labour-intensiveness can significantly impact on everyday clinical activities. For instance, due to its patient acceptability, CCE-2 has been proposed as a possible "filter" or screening test for the selection of patients for conventional colonoscopy (39,41). Nevertheless, the amount of resources and manpower required for the provision of such service may place further strain on already-overstretched healthcare services.…”
Section: Limitations Faced By Ccementioning
confidence: 99%
“…A few studies comparing it to virtual colonoscopy in patients with incomplete colonoscopy were published with good results (16,17).…”
Section: Colon Capsule Endoscopy (Cce)-currentmentioning
confidence: 99%