2020
DOI: 10.1136/bjophthalmol-2020-315882
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of common IOL power formulas in 611 eyes based on axial length and corneal power ranges

Abstract: AimsTo provide clinical guidance on the use of intraocular lens (IOL) power calculation formulas according to the biometric parameters.Methods611 eyes that underwent cataract surgery were retrospectively analysed in subgroups according to the axial length (AL) and corneal power (K). The predicted residual refractive error was calculated and compared to evaluate the accuracy of the following formulas: Haigis, Hoffer Q, Holladay 1 and SRK/T. Furthermore, the percentages of eyes with ≤±0.25, ≤±0.5 and 1 dioptres … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
18
1
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(22 citation statements)
references
References 31 publications
2
18
1
1
Order By: Relevance
“…21 However, the percentage of PE within ±0.50 D was reported to reduce by 75% in long eyes and by 55% to 70% in eyes combined with a long AL and flat K, which indicates that long eyes and flat corneal curvatures in CEL may partly contribute to the inaccuracy of the IOL power calculations in our study. 31,32 In this study, the MAE of different formulas ranged from 0.63 to 0.75 D, greater than in normal cataract surgery. 27 Similarly, MAE were found to be more than 0.70 D with a flanged intrascleral IOL fixation, suggesting that, in cases where IOLs that were not implanted in the capsular bag, the accuracy of these formulas could be compromised.…”
Section: Discussionmentioning
confidence: 53%
“…21 However, the percentage of PE within ±0.50 D was reported to reduce by 75% in long eyes and by 55% to 70% in eyes combined with a long AL and flat K, which indicates that long eyes and flat corneal curvatures in CEL may partly contribute to the inaccuracy of the IOL power calculations in our study. 31,32 In this study, the MAE of different formulas ranged from 0.63 to 0.75 D, greater than in normal cataract surgery. 27 Similarly, MAE were found to be more than 0.70 D with a flanged intrascleral IOL fixation, suggesting that, in cases where IOLs that were not implanted in the capsular bag, the accuracy of these formulas could be compromised.…”
Section: Discussionmentioning
confidence: 53%
“…Although IOL power calculation began as an optical approach using theoretical formulas, the majority of methods used in clinical practice over the past 25 years are based on empirical methods that have used “fudged” formulas to compensate for the unknowns in the system. [ 8 9 ] However, the advent of better diagnostic equipment and ever-improving surgical techniques have decreased the number of unknowns, and optical methods now hold sway in IOL power calculation. For comparison, the mean numerical prediction error using the latest generation IOL power calculation formula (Olsen 2007) on the same dataset was found to be 0.00 ± 0.58D with a mean absolute error of 0.47D.…”
Section: Discussionmentioning
confidence: 99%
“…Two experienced surgeons specializing in uveitis (KK and HT) performed all surgeries using the same surgical procedure and topical anesthesia. The surgical procedures were standardized 21 23 . A 2.5-mm, clear corneal/scleral incision was created at the 12 o’clock position.…”
Section: Methodsmentioning
confidence: 99%