2022
DOI: 10.1016/j.prosdent.2021.01.016
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of impressions for multiple implants: A comparative study of digital and conventional techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(19 citation statements)
references
References 37 publications
0
19
0
Order By: Relevance
“…Although Alshabarty et al [ 41 ] described itself as an in vivo study, it could be classified as in vitro because the reference models used, although they proceeded from impressions taken in patients, were effectively in vitro models. In this case, 14 articles investigated cases of CE exclusively [ 11 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 ], nine of PE [ 41 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 ], two of SI [ 63 , 64 ] and another included both CE and SI models [ 65 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Although Alshabarty et al [ 41 ] described itself as an in vivo study, it could be classified as in vitro because the reference models used, although they proceeded from impressions taken in patients, were effectively in vitro models. In this case, 14 articles investigated cases of CE exclusively [ 11 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 ], nine of PE [ 41 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 ], two of SI [ 63 , 64 ] and another included both CE and SI models [ 65 ].…”
Section: Resultsmentioning
confidence: 99%
“…Of the 15 in vitro studies that simulated CE, six reported greater accuracy with DI [ 43 , 44 , 45 , 50 , 52 , 65 ], four found no difference [ 42 , 46 , 48 , 53 ] and five reported greater accuracy with CI [ 11 , 47 , 49 , 51 , 54 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The literature indicates that the implant digital impression is influenced by the scan body, 11 12 the number of implants, 2 13 14 the span of scanning, 2 3 15 16 17 the alignment, location and depth of implants, 5 6 14 18 the scanned surface morphology, and access to the relevant surfaces, 19 20 21 22 23 24 and the scanning path. 25 However, to the knowledge of authors, studies investigating the effect of adjacent teeth on digital scanning of implants are lacking in the literature.…”
Section: Introductionmentioning
confidence: 99%