2019
DOI: 10.1038/s41433-019-0485-0
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of intraocular lens calculations based on fellow-eye biometry for phacovitrectomy for macula-off rhegmatogenous retinal detachments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
21
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 19 publications
0
21
0
Order By: Relevance
“…Preoperative AL, ACD and LT of RRD eyes were measured using an IOLMaster 700 (Carl Zeiss Meditec Ltd., Jena, Germany) as formerly described [ 14 , 15 ]. According to Kunavisarut [ 13 ] and El-Khayat [ 16 ], only measurements from an IOLMaster with a signal-to-noise ratio (SNR) value greater than 2 were included. Postoperative measurements were also obtained using the IOLMaster 700 with silicone oil-filled phakic eyes program before silicone oil removal.…”
Section: Methodsmentioning
confidence: 99%
“…Preoperative AL, ACD and LT of RRD eyes were measured using an IOLMaster 700 (Carl Zeiss Meditec Ltd., Jena, Germany) as formerly described [ 14 , 15 ]. According to Kunavisarut [ 13 ] and El-Khayat [ 16 ], only measurements from an IOLMaster with a signal-to-noise ratio (SNR) value greater than 2 were included. Postoperative measurements were also obtained using the IOLMaster 700 with silicone oil-filled phakic eyes program before silicone oil removal.…”
Section: Methodsmentioning
confidence: 99%
“…As the advances emerging in microsurgical instrumentation on small-gauge vitrectomy, combined surgery has, therefore, become a popular procedure in treating RRD [5][6][7] . A high level of consistency of AL measured before and after PPV has been shown in both macula-sparing RRD cases [8] and macula-off RRD cases [1,2] . In RRD cases treated by combined surgery, selection of the IOL power using AL data measured before PPV is reported to result in a small biometric error and a small myopic shift that is within the tolerable range in most cases [9] .…”
mentioning
confidence: 73%
“…Alternatively, it has been reported intraocular lens calculations using fellow-eye biometry for phacovitrectomy for macula off rhegmatogenous retinal detachments are accurate and better than those from same-eye biometry [2] . It was found in our study, the difference of AL between the affected eye and the fellow eye was greater before PPV than that before SOR in patients with RRD-CD.…”
Section: Factors That May Be Related To the Variation Of Al Measured mentioning
confidence: 99%
See 2 more Smart Citations