Accuracy of pencil‐beam redefinition algorithm dose calculations in patient‐like cylindrical phantoms for bolus electron conformal therapy

Abstract: The measured data, whose high precision makes them useful for evaluation of the accuracy of electron dose algorithms, will be made publicly available. Based on the spread in dose differences, the PBRA has at least twice the accuracy of the PBA. From a clinical perspective the PBRA accuracy is acceptable in the retromolar trigone and nose for electron therapy with and without bolus.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 13 publications
(40 citation statements)
references
References 42 publications
0
24
0
Order By: Relevance
“…Eclipse eMC commissioning data were measured at Mary Bird Perkins Cancer Center (MBPCC) for a 16 MeV (Enormalp,0=16.6MeV) beam on a Clinac EX (Varian Medical Systems) for the 15×15cm2 and 10×10cm2 applicators, the same linear accelerator Carver et al (9) used for the standard measured dataset. Beam scanning was performed using a RFA‐200 Water Phantom 2D scanning tank and OmniPro scanning software (IBA Dosimetry, Bartlett, TN).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Eclipse eMC commissioning data were measured at Mary Bird Perkins Cancer Center (MBPCC) for a 16 MeV (Enormalp,0=16.6MeV) beam on a Clinac EX (Varian Medical Systems) for the 15×15cm2 and 10×10cm2 applicators, the same linear accelerator Carver et al (9) used for the standard measured dataset. Beam scanning was performed using a RFA‐200 Water Phantom 2D scanning tank and OmniPro scanning software (IBA Dosimetry, Bartlett, TN).…”
Section: Methodsmentioning
confidence: 99%
“…Electron dose distributions calculated using the eMC algorithm were compared to a publicly‐available measured dataset consisting of multiple point‐dose measurements for two cylindrical patient‐like phantoms in the presence of conformal bolus (9) . The two cylindrical phantoms used in this study were the same ones Hogstrom et al (10) used to evaluate the accuracy of the first commercial implementation of the PBA for patients previously treated for a retromolar trigone and nose cancer.…”