2014
DOI: 10.1089/dia.2013.0221
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Subcutaneous Continuous Glucose Monitoring in Critically Ill Adults: Improved Sensor Performance with Enhanced Calibrations

Abstract: Objective: Accurate real-time continuous glucose measurements may improve glucose control in the critical care unit. We evaluated the accuracy of the FreeStyle Ò Navigator Ò (Abbott Diabetes Care, Alameda, CA) subcutaneous continuous glucose monitoring (CGM) device in critically ill adults using two methods of calibration. Subjects and Methods: In a randomized trial, paired CGM and reference glucose (hourly arterial blood glucose [ABG]) were collected over a 48-h period from 24 adults with critical illness (me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(36 citation statements)
references
References 24 publications
0
36
0
Order By: Relevance
“…To our knowledge, no scientific studies have been published previously evaluating the feasibility of factory calibration besides the ones leading to FreeStyle Libre. [9][10][11][12][13] All calibration-related studies and publications were focused on understanding and improving the standard BG-based fingerstick calibration [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30] or overcoming transient effects, such as lag and signal artifacts [31][32][33][34][35] that can impact calibration. This demonstrates the novelty of this alternative approach and also possibly the superiority of the chemistry used in FreeStyle Libre over other sensor systems.…”
Section: Implementation Of Factory Calibration For Freestyle Librementioning
confidence: 99%
“…To our knowledge, no scientific studies have been published previously evaluating the feasibility of factory calibration besides the ones leading to FreeStyle Libre. [9][10][11][12][13] All calibration-related studies and publications were focused on understanding and improving the standard BG-based fingerstick calibration [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30] or overcoming transient effects, such as lag and signal artifacts [31][32][33][34][35] that can impact calibration. This demonstrates the novelty of this alternative approach and also possibly the superiority of the chemistry used in FreeStyle Libre over other sensor systems.…”
Section: Implementation Of Factory Calibration For Freestyle Librementioning
confidence: 99%
“…Improvements in accuracy of the FreeStyle Navigator device may be obtained by performing calibrations more frequently. 14 Another open-label study investigated the use of the GluCath IA-CGM device in cardiac surgery patients admitted to the ICU and reported similar accuracy with an aggregate MARD of 13.0% (individual sensors ranging from 4.7% to 33.5%). 15 As in all studies in this field, the extent of acceptable deviation between sensor and arterial reference glucose measurements can be debated.…”
Section: Discussionmentioning
confidence: 89%
“…This review excluded studies evaluating CGM accuracy and reliability, which have been reviewed previously. [23][24][25][26][27][28][29][30][31] While we reference isolated inpatient non-ICU CGM cases, we primarily included observational and randomized CGM glycemic outcome studies in this review (six ICU studies, three non-ICU studies), reflecting the scarcity of evidence on this topic, and the need for further studies.…”
Section: Search Methodsmentioning
confidence: 99%
“…As of 2011, the Endocrine Society recommended against inpatient CGM due to lack of published safety and efficacy data. 22 Since that time, numerous publications have evaluated inpatient CGM accuracy, reliability, and safety; [23][24][25][26][27][28][29][30][31] however, few studies have evaluated the glycemic outcomes of subcutaneous CGM, which are limited by the lack of Type 1 Diabetes Mellitus (T1DM) subjects and the use of different CGM systems. This article will review subcutaneous CGM glycemic outcomes in the adult ICU and non-ICU setting.…”
Section: Review Articlementioning