2016
DOI: 10.15403/jgld.2014.1121.253.epq
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of the ElastPQ® Technique for the Assessment of Liver Fibrosis in Patients with Chronic Hepatitis C: a “Real Life” Single Center Study

Abstract: Background & Aims: Noninvasive assessment of liver stiffness has been increasingly used to evaluate fibrosis instead of liver biopsy, especially in patients with chronic viral hepatitis. The aim of this study was to assess the performance in staging liver fibrosis of the updated ElastPQ® technique (EPIQ7 ultrasound system, Philips Healthcare, Bothell, WA, USA) in the “real life” setting by using the FibroScan as the reference standard and to understand whether the use of the quality criteria improves the p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
41
1
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 51 publications
(45 citation statements)
references
References 11 publications
2
41
1
1
Order By: Relevance
“…Their acquisition methods and reliability characteristics are described elsewhere [18]. We used the following cut-off values: mild/no fibrosis (F0-1), 4.1-5.5 kPa; significant fibrosis (F2), 5.51-7.5 kPa; advanced fibrosis (F3), 7.51-11.00 kPa; liver cirrhosis (F4) >11.01 kPa [19,20].…”
Section: Ultrasound and Elastographymentioning
confidence: 99%
“…Their acquisition methods and reliability characteristics are described elsewhere [18]. We used the following cut-off values: mild/no fibrosis (F0-1), 4.1-5.5 kPa; significant fibrosis (F2), 5.51-7.5 kPa; advanced fibrosis (F3), 7.51-11.00 kPa; liver cirrhosis (F4) >11.01 kPa [19,20].…”
Section: Ultrasound and Elastographymentioning
confidence: 99%
“…In univariate and multivariate analysis, an IQR/M ≥ 30 % was associated with a discordance of at least 2 stages of fibrosis between SWS and histological fibrosis. Using ElastPQ ® , a recent study has suggested that an IQR/ M ≤ 30 % is the most important quality criterion, whereas the number of measurements seems not to affect the performance, provided that they are at least five [73]. Thus, the compliance with quality criteria may increase the diagnostic accuracy of pSWE [68,72].…”
Section: Quality Criteriamentioning
confidence: 99%
“…Ten valid measurements were performed and the median value was calculated and expressed in kPa. Reliable measurements were considered the median value of 10 valid LS measurements with an interquartile range/median <30% (IQR/Median <30%) recommended by The Society of Radiologists in Ultrasound [17] and proven by the Ferraioli at al study [18]. For fibrosis estimation we used the cutoffs proposed by Mare et al [19] (Table I).…”
Section: Elastographic Measurementsmentioning
confidence: 99%