2016
DOI: 10.1016/j.ajo.2016.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Total Corneal Astigmatism Measurements With a Scheimpflug Imager and a Color Light-Emitting Diode Corneal Topographer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
22
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 19 publications
1
22
0
Order By: Relevance
“…) and specular reflections (Klijn et al. ), measure keratometric astigmatism (KA) and posterior corneal astigmatism (PCA) separately. These methods may also provide a total corneal astigmatism (TCA), based on Snell′s law (Koch et al.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…) and specular reflections (Klijn et al. ), measure keratometric astigmatism (KA) and posterior corneal astigmatism (PCA) separately. These methods may also provide a total corneal astigmatism (TCA), based on Snell′s law (Koch et al.…”
Section: Introductionmentioning
confidence: 99%
“…Newer technologies, such as Scheimpflug camera imaging (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Naeser et al 2017), optical coherence tomography (Ueno et al 2014) and specular reflections (Klijn et al 2016), measure keratometric astigmatism (KA) and posterior corneal astigmatism (PCA) separately. These methods may also provide a total corneal astigmatism (TCA), based on Snell 0 s law (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Klijn et al 2016;Fredriksson & Behndig 2017;Nae et al 2017).…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, toric calculators, such as Panacea IOL & Toric Calculator, consider real measurements of anterior and posterior toricity with the correction from keratometric to real corneal refractive index 42. Although the use of direct measurements of the anterior and posterior cornea is helpful in decreasing resultant astigmatism after toric IOL implantation,33,43,44 there are studies demonstrating that the outcomes achieved using these measurements or software are not better than those achieved with the Barrett’s toric calculator 24,45…”
Section: Resultsmentioning
confidence: 99%
“…Optical coherence tomography (OCT) and Scheimpflug anterior segment analysis systems can directly measure the posterior cornea surface, which is more accurate than corneal topography systems [20,21]. The reliability and repeatability of Pentacam have been clinically proven for corneal astigmatism measurements [22,23].…”
Section: Discussionmentioning
confidence: 99%