Accuracy of x-ray image-based 3D localization from two C-arm views: a comparison between an ideal system and a real device

Abstract: C-arm X-ray imaging devices are commonly used for minimally invasive cardiovascular or other interventional procedures. Calibrated state-of-the-art systems can, however, not only be used for 2D imaging but also for three-dimensional reconstruction either using tomographic techniques or even stereotactic approaches.To evaluate the accuracy of X-ray object localization from two views, a simulation study assuming an ideal imaging geometry was carried out first. This was backed up with a phantom experiment involvi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
4
4
1

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…For the simulation, we computed 250 spheres each at a different positions in 3-D space within a maximum distance to the center of the volume of 150 mm and with a radius between 5 mm and 15 mm. The simulation was performed using ideal C-arm projection matrices as described in [15,16]. The C-arm positions were chosen to be 90 o apart which is similar to a clinical setup.…”
Section: Evaluation and Resultsmentioning
confidence: 99%
“…For the simulation, we computed 250 spheres each at a different positions in 3-D space within a maximum distance to the center of the volume of 150 mm and with a radius between 5 mm and 15 mm. The simulation was performed using ideal C-arm projection matrices as described in [15,16]. The C-arm positions were chosen to be 90 o apart which is similar to a clinical setup.…”
Section: Evaluation and Resultsmentioning
confidence: 99%
“…In the next step, we applied the motion estimated by catheter tracking to the catheter tip to move it from its 3-D position in the previous frame to the next frame. Finally, we compared the 3-D position reached by applying the estimated motion to the actual 3-D reference point obtained by triangulation [23,24]. In the end, the error was calculated as the Euclidean distance in 3-D space.…”
Section: Model-based Catheter Trackingmentioning
confidence: 99%
“…The special case implies that there was one ellipse in one view, while it collapsed to a line in the other view. The projection matrices for the simulation were computed as described in [23,24].…”
Section: Model Generationmentioning
confidence: 99%
“…Given the rotation and translation, the central rays r A , r B ∈ R 3 for both cones can be calculated and intersected by the method presented in [15] to find the center of the reconstructed sphere w c ∈ R 3 . To calculate the radius of the reconstructed sphere, each cone is intersected with a 3-D plane parallel to the imaging plane at the position of the calculated center w c .…”
Section: ×4mentioning
confidence: 99%