Accurate and Precise Wavelength Calibration for Wide Bandwidth Array Spectrometers

Abstract: Calibrating the wavelength scale of an array spectrometer typically involves measurements of lines at well-known wavelengths from a calibration lamp such as a mercury-argon source. This process is relatively straightforward when the lines are well separated, relative to the bandwidth of the spectrometer. When the spectrometer's bandwidth is large, compared with the distance between calibration wavelengths, it becomes increasingly difficult to accurately locate lines in the calibration spectrum. Even calibratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 12 publications
0
20
0
Order By: Relevance
“…This calibrated apparatus adopts the Model 6034 pencil lamp from Oriel Instruments. The criterion for the Figure 14 presents the architecture of the calibrated spectrometer linking 198 Hg discharged lamp which utilizes spectral lines to calibrate the spectrometer in the visual spectrum [20][21][22]. This calibrated apparatus adopts the Model 6034 pencil lamp from Oriel Instruments.…”
Section: Methodsmentioning
confidence: 99%
“…This calibrated apparatus adopts the Model 6034 pencil lamp from Oriel Instruments. The criterion for the Figure 14 presents the architecture of the calibrated spectrometer linking 198 Hg discharged lamp which utilizes spectral lines to calibrate the spectrometer in the visual spectrum [20][21][22]. This calibrated apparatus adopts the Model 6034 pencil lamp from Oriel Instruments.…”
Section: Methodsmentioning
confidence: 99%
“…CIExyY colour distribution of A1, A2, B1 and B2 Figure 14 present the architecture of the calibrated spectrometer linking 198 Hg discharged lamp, which utilizes the measurement of spectral line to calibrate the spectrometer of spectral line in the visual spectrum [18][19][20]. This calibrated apparatus adopts the Oriel Instruments, model 6034 pencil lamp.…”
Section: Profile Of Cie Y For A1 and A2mentioning
confidence: 99%
“…Manufacturers often employ a third order polynomial for the wavelength calibration of their spectroradiometers. 40 Once the polynomial coefficients in Equation 11 have been determined, the wavelength correction D k is determined through…”
Section: Calibration Of the Wavelength Scalementioning