2011
DOI: 10.1109/tpwrd.2010.2089473
|View full text |Cite
|
Sign up to set email alerts
|

Accurate Assessment of Harmonic and Interharmonic Currents Generated by VSI-Fed Drives Under Unbalanced Supply Voltages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(23 citation statements)
references
References 15 publications
0
23
0
Order By: Relevance
“…The problem of modeling waveform distortions due to PWM ASD has been studied extensively and reported in the relevant literature [5][6][7][8][9]. In particular, in [6], it was shown that ASDs based on double-stage conversion systems generate interharmonic current components in the supply system side, DC link, and output side, in addition to harmonics that are typical for single-stage converters.…”
Section: Ac Supply Side Spectral Component Frequenciesmentioning
confidence: 99%
See 2 more Smart Citations
“…The problem of modeling waveform distortions due to PWM ASD has been studied extensively and reported in the relevant literature [5][6][7][8][9]. In particular, in [6], it was shown that ASDs based on double-stage conversion systems generate interharmonic current components in the supply system side, DC link, and output side, in addition to harmonics that are typical for single-stage converters.…”
Section: Ac Supply Side Spectral Component Frequenciesmentioning
confidence: 99%
“…In [7], the authors presented an analytical approach for characterizing harmonic and interharmonic currents generated by ASDs under ideal supply conditions. Recently, reference [8] extended the previous work [7] by developing an efficient and accurate approach for characterising both harmonic and interharmonic currents when the ASDs were operated under unbalanced supply conditions. Finally, reference [9] presented simulation results by using MATLAB/Simulink for the assessment of harmonic and interharmonic currents generated by the ASDs in which the commutation effects caused by source impedance and non-ideal supply voltages were included.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…(iv) Iterative harmonic analysis is unable to model non-linear load. For the above reasons, the research work in interharmonics measurement is still on the way [25][26][27][28][29][30][31][32][33][34][35][36][37][38].…”
Section: Introductionmentioning
confidence: 99%
“…In spite of all these advantages, VSD are mainly affected by interharmonics. The appearance of interharmonics in the drive is due to the current imbalance or the overmodulation of the inverter is given in [1][2][3][4][5][6][7]. The main cause for the appearance of interharmonics in ACIDC/ AC system is that the two AC systems are not properly decoupled by the DC link and all loads not pulsating synchronously with the system frequency.…”
Section: Introductionmentioning
confidence: 99%