2007
DOI: 10.1016/j.chroma.2007.09.093
|View full text |Cite
|
Sign up to set email alerts
|

Accurate automated logPo/w measurement by gradient-flow liquid–liquid partition chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…Since the reported log P oct values are 2.6 for FT (15) and 2.2-2.3 for NT (33,34), respectively, FT has not only higher hydrophobicity but also higher lipophilicity than NT. Therefore, if these drugs are encapsulated in LNE particles, FT should show a higher EE% value than NT.…”
Section: Calculated K P Valuesmentioning
confidence: 99%
“…Since the reported log P oct values are 2.6 for FT (15) and 2.2-2.3 for NT (33,34), respectively, FT has not only higher hydrophobicity but also higher lipophilicity than NT. Therefore, if these drugs are encapsulated in LNE particles, FT should show a higher EE% value than NT.…”
Section: Calculated K P Valuesmentioning
confidence: 99%
“…Rejection of PPCP is based on charge interaction of PPCP (pKa values) and membrane, MWCO, and hydrophobicity interactions [25]. Hydrophobicity of PPCPs is measured by log P value where P is defined as the ratio of the concentrations of a solute in octonol to that in water [30]. PPCPs rejections presented in Table 4 are explained using these mechanisms below.…”
Section: Rejection Of Pharmaceuticals and Personal Care Productsmentioning
confidence: 99%
“…They predicted that poor absorption or permeation into cells for a molecule is more likely when the number of hydrogen‐bond donors > 5, the number of hydrogen‐bond acceptors > 10, the relative molecular mass > 500 and the calculated log P (cLog P ) > 5. This last in particular is a measure of lipophilicity, and those who design chemical libraries will always seek molecules that obey the Ro5, including through experimental measurements of the partition coefficient log P and/or the distribution coefficient log D . Note, however, that natural product‐based drugs (still a major source of leads and indeed marketed drugs; see below) very rarely, if ever, obey the Ro5 and, indeed, even some synthetic drugs have very large molecular weights ; for example, navitoclax dihydrochloride , a Bcl‐2 inhibitor, has seven ring systems and a relative molecular mass of 1047.5.…”
Section: Drug Biophysics and The Rule‐of‐5mentioning
confidence: 99%