2013
DOI: 10.1016/j.aca.2013.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Accurate measurement of bromine contents in plastic samples by instrumental neutron activation analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…No γ‐ray peaks from 76 Se, 122 Sb, and/or 110 Ag were found, because the samples were prepared with pure solutions and cellulose filter papers, only. Small amount of 82 Br was found from the cellulose filter papers . But γ‐ray peaks of 82 Br were so small and well separated from the γ‐ray peaks of 76 As as shown in Figure (a) and did not cause any interference either.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…No γ‐ray peaks from 76 Se, 122 Sb, and/or 110 Ag were found, because the samples were prepared with pure solutions and cellulose filter papers, only. Small amount of 82 Br was found from the cellulose filter papers . But γ‐ray peaks of 82 Br were so small and well separated from the γ‐ray peaks of 76 As as shown in Figure (a) and did not cause any interference either.…”
Section: Resultsmentioning
confidence: 99%
“…The total content of arsenic in the candidate reference material of the AsB standard solution was measured by INAA using standard comparator method . Ten representative bottles from a batch of AsB standard solutions were selected including the first and the last bottles.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Br-ISE was calibrated in the KBr (10 −6 -10 −1 M) solutions that were prepared in deionized water for 200 s. The effect of the pH value of the solution on the Br-ISE response potential was studied by calibrating the potential of Br-ISE in 10 −3 M KBr solutions with different pH values (2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13).…”
Section: Characterizationmentioning
confidence: 99%
“…However, the bromine industry normally use titration to measure the bromine concentrations. Methods to detect the concentration of bromide and other halogens in water include neutron activation analysis, inductively coupled plasma mass spectrometry, ion and liquid chromatography, and fluorescence spectroscopy [6][7][8][9][10][11]. Although these methods are highly mature and could obtain results with high accuracy and precision, complex procedures and expensive equipment limited these methods.…”
Section: Introductionmentioning
confidence: 99%