This paper analyses the impact on workers of the electromagnetic field produced by large furnaces for glass production. The paper also propose a solution for the reduction and the containment of magnetic induction levels below the limits imposed by national and international directives. Using a threedimensional numerical calculation code based on the hypothesis of filiform conductors in the air (Biot-savart law). The choice of the solution is based on the technique named highly coupled magnetically passive loop technique (HMCPL). The solution was then implemented and a comparison between the magnetic induction values before and after the installation of the shielding solution is presented.INDEX TERMS Magnetic field pollution, shielding system.