Accurate quantification of dimethylamine (DMA) in human plasma and serum by GC–MS and GC–tandem MS as pentafluorobenzamide derivative in the positive-ion chemical ionization mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
31
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 30 publications
(32 citation statements)
references
References 22 publications
1
31
0
Order By: Relevance
“…The DMA concentrations used in the validation experiment are relevant and were usually measured in liver homogenates after incubation with ADMA at final added concentrations of up to 100 M (see below). Thus, quantitative determination of DMA as pentafluorobenzamide derivative by the present GC-MS method seems to proceed with the same accuracy and precision in rat liver homogenate, human plasma [2] and human urine [3]. The internal standard d 6 -DMA was used in all experiments of the present work at a fixed concentration of 10 M, like in human plasma and serum [2], in order to cover the whole DMA concentration range.…”
Section: Intra-assay Precision and Accuracy Of The Methods For Dma Quamentioning
confidence: 97%
See 3 more Smart Citations
“…The DMA concentrations used in the validation experiment are relevant and were usually measured in liver homogenates after incubation with ADMA at final added concentrations of up to 100 M (see below). Thus, quantitative determination of DMA as pentafluorobenzamide derivative by the present GC-MS method seems to proceed with the same accuracy and precision in rat liver homogenate, human plasma [2] and human urine [3]. The internal standard d 6 -DMA was used in all experiments of the present work at a fixed concentration of 10 M, like in human plasma and serum [2], in order to cover the whole DMA concentration range.…”
Section: Intra-assay Precision and Accuracy Of The Methods For Dma Quamentioning
confidence: 97%
“…Because tissue homogenate in PBS resembles plasma or serum rather than urine with respect to protein concentration, DMA concentration expected to be formed, and pH, the derivatization/extraction procedure used in the present study is almost identical with that used for plasma and serum samples previously [2]. Samples were vortex-mixed manually using a Heidolph vortex mixer model Reax 2000 (Schwabach, Germany) at the highest vortex speed (i.e.…”
Section: Sample Derivatization and Extractionmentioning
confidence: 99%
See 2 more Smart Citations
“…According to the literature, GC or GC-MS combined with extraction and derivatization was developed for the analysis of aliphatic amines in various samples. For example, Chobanyan et al developed pentafluorobenzoyl chloride derivatization coupled with solvent extraction for GC analysis of the dimethylamine in human blood [9]. Toro et al, Zhao et al and Mishra et al applied derivatization followed by solid-phase extraction and GC-MS to the analysis of aliphatic amines in water samples [10][11][12].…”
Section: Introductionmentioning
confidence: 99%