1960
DOI: 10.1021/j100834a026
|View full text |Cite
|
Sign up to set email alerts
|

ACIDITY MEASUREMENTS WITH THE GLASS ELECTRODE IN H2O-D2O MIXTURES

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
158
0

Year Published

1971
1971
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 244 publications
(160 citation statements)
references
References 0 publications
2
158
0
Order By: Relevance
“…The correction pD = pH measured + 0.4 was applied to the pH meter readings [15,16]. Kinetic runs were run in duplicate to give a reproducibility of ±15%.…”
Section: Uv Kinetic Measurementsmentioning
confidence: 99%
“…The correction pD = pH measured + 0.4 was applied to the pH meter readings [15,16]. Kinetic runs were run in duplicate to give a reproducibility of ±15%.…”
Section: Uv Kinetic Measurementsmentioning
confidence: 99%
“…1,4,7-Triazacyclononane (tacn) was synthesized according to a modified literature procedure (Supporting Information). [56] 1 H and 31 P NMR spectra were recorded on a Jeol EXC-400 spectrometer and referenced to TMS or the solvent residual peak as [57,58] The pD values were adjusted using concentrated DNO 3 and NaOD solutions. UV/Vis measurements were carried out on a Varian Cary 50 scan spectrophotometer coupled to a Grant thermostatted water circulation bath.…”
Section: Nnјnјј-tris(p-tolylsulfonyl)-147-triazacyclononanementioning
confidence: 99%
“…The correction pD = pH measured + 0.4 was applied to the pH meter readings. [57,58] Kinetic runs were run in duplicate to give a reproducibility of Ϯ15 %.…”
Section: 6-mentioning
confidence: 99%
“…Instead of comparative measurements on two separately prepared samples, the RCs from a highly concentrated stock (N 300 μM) in H 2 O (or D 2 O) were diluted into D 2 O (or H 2 O) gradually while the salt and detergent concentrations were held constant. The observed rates were plotted as a function of dilution and a linear fit to the measured rates offered k -ion concentration for the glass electrode solvent isotope artifact [32,33]. The "apparent pH" means the actual pH meter reading.…”
Section: Hydrogen Isotope Measurementsmentioning
confidence: 99%
“…sphaeroides, 183 the cultivation, and the preparation of RC protein have been 184 described previously. 19 The UQ at the Q B site was removed as 185 described previously 32 and reconstituted by addition of RQ in 186 large (>10) excess over RC. The occupancy of the Q B site was 187 >70% as determined from the ratio of the amplitudes of the 188 slow and fast phases of the charge recombination measured at 189 865 nm.…”
Section: áGnesmentioning