ACT2: a High Heat Flux Test Facility Using Electron Beam for Fusion Application

Abstract: ACT2 (Active Cooling Teststand 2), a high heat flux test facility using electron beam has been upgraded from ACT facility and started the operation. A new electron gun enables the steady state and transient heat load on actively cooled samples. ACT2 can achieve large loaded area with steady state reactor relevant heat flux (∼ 20 MW/m 2 ) up to 200 × 200 mm 2 and simulation of edge localized modes with short pulse length (∼ 100 µs).Beam profile was obtained about 9 mm with graphite probes. The heat flux is obta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 10 publications
0
13
0
Order By: Relevance
“…The heat removal experiments were conducted using the active cooling test stand 2 (ACT2) in the National Institute for Fusion Science [15]. Figure 2 depicts the experimental setup for the heat removal experiment.…”
Section: Heat Removal Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…The heat removal experiments were conducted using the active cooling test stand 2 (ACT2) in the National Institute for Fusion Science [15]. Figure 2 depicts the experimental setup for the heat removal experiment.…”
Section: Heat Removal Experimentsmentioning
confidence: 99%
“…The present work intends to evaluate the heat transfer coefficient of the water-cooling channel with a V-shaped staggered rib (ribbed channel) in the target system of the accelerator driven neutron source. Heat load tests were performed to experimentally evaluate the heat transfer coefficient by setting a target base plate with the same water-cooling transfer system in an active cooling test stand [15] and an irradiating electron beam on the target plate. The target plate and cooling water temperatures were monitored by thermocouples.…”
Section: Introductionmentioning
confidence: 99%
“…High heat load test machine ACT2 (Active Cooling Teststand 2), with 40 keV and ~300 kW electron beam, has been used for characterizing high heat flux test components and materials 30 .…”
Section: Ii-b Major Fusion Engineering Facilities In Nifs and Their C...mentioning
confidence: 99%
“…High Heat Flux Test (ACT2) 30 Ion Beam Surface Analysis 33 High heat flux test of W/Cu-alloy joints 31 Properties of re-solidified W 32 RBS for ion-implanted RAFM 33 Tritium Control of low level tritium…”
Section: Research Subjects Major Emphases Key Facilities In Nifs Exam...mentioning
confidence: 99%
“…Thus, erosion caused by the transient loads should be well investigated. High heat flux tests have been conducted by electron beam devices [6][7][8] and plasma guns [9][10][11]. These studies revealed that the erosion amounts can be summarized in the heat flux factor F HF = ε ⊥ τ −0.5 where author's e-mail: kibano@eei.eng.osaka-u.ac.jp ε ⊥ is the energy density into the target surface and τ is the heat pulse duration [1,12].…”
Section: Introductionmentioning
confidence: 99%