2016
DOI: 10.4314/ajtcam.v13i1.19
|View full text |Cite
|
Sign up to set email alerts
|

Activation of different cerebral functional regions following acupuncture at Bot H Taixi and Taichong acupoints and taixi acupointalone: An fMRI study

Abstract: Background: To explore the brain function regions characteristics of the acupoint combination, this study observed activity changes in the brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…The MRI data (resting-state BOLD sequence) were collected at 15 min before needling and 15 min after withdrawing the needle. The scanning parameters are the same as those in our previous study [ 25 ]. The scanning methods are (1) transverse T1-weighted image (T1WI) sequence: 1 min, 51 s, fast spin echo sequence; OAx T1 FLAIR, repetition time: 1750 ms/echo time: 24 ms, inversion time: 960 ms, field of view: 24 cm × 24 cm/ Z , matrix: 320 × 224/number of excitations = 1, thickness: 5.0 mm/interval: 1.0 mm, 30 slices total, echo train length: 8, and bandwidth: 31.25; (2) resting-state fMRI BOLD data collection: gradient echo-echo-planar imaging sequence scanning was conducted for 6 min in accordance with the following parameters: repetition time: 3000 ms/minimum, echo time: minimum, flip angle: 90, field of view: 240 mm × 240 mm, thickness: 5.0 mm/interval: 1.0 mm, 30 slices each time, and matrix: 96 × 96/number of excitations = 1.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The MRI data (resting-state BOLD sequence) were collected at 15 min before needling and 15 min after withdrawing the needle. The scanning parameters are the same as those in our previous study [ 25 ]. The scanning methods are (1) transverse T1-weighted image (T1WI) sequence: 1 min, 51 s, fast spin echo sequence; OAx T1 FLAIR, repetition time: 1750 ms/echo time: 24 ms, inversion time: 960 ms, field of view: 24 cm × 24 cm/ Z , matrix: 320 × 224/number of excitations = 1, thickness: 5.0 mm/interval: 1.0 mm, 30 slices total, echo train length: 8, and bandwidth: 31.25; (2) resting-state fMRI BOLD data collection: gradient echo-echo-planar imaging sequence scanning was conducted for 6 min in accordance with the following parameters: repetition time: 3000 ms/minimum, echo time: minimum, flip angle: 90, field of view: 240 mm × 240 mm, thickness: 5.0 mm/interval: 1.0 mm, 30 slices each time, and matrix: 96 × 96/number of excitations = 1.…”
Section: Methodsmentioning
confidence: 99%
“…The preprocessing procedures are the same as those in our previous study [ 25 ], which include (1) converting DICOM to NIFTI, (2) slice timing after removing first 10 time points, (3) realigning and excluding subjects with max head motion > 1.5 mm on any axis and head rotation > 1.5 degrees, (4) segmenting and affixer regularization according to East Asians, (5) normalizing by using EPI templates, (6) smoothing images with a Gaussian kernel with isotropic full-width at half-maximum (FWHM) of 6 mm, and (7) removing the linear tendency of the data.…”
Section: Methodsmentioning
confidence: 99%
“…The catalytic activity of sil ver containing catalysts in this reaction is caused by the formation, on the silver particle surface, of highly active oxygen incorporated in the surface oxide [5][6][7]. It is known that the presence of hydroxyl ions in the reaction medium facilitates the rupture of the C-H bond and promotes methanal oxidation with oxygen [8][9][10]. Nevertheless, high conversions of methanal are observed only at elevated temperatures.…”
mentioning
confidence: 99%