2015 4th International Conference on Electrical Engineering (ICEE) 2015
DOI: 10.1109/intee.2015.7416841
|View full text |Cite
|
Sign up to set email alerts
|

Active and reactive power control of DFIG using PI and DPC controllers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…The orientation condition is given by the following relation [1–5]:{1em4ptφnormalsd=φsφnormalsq=0false⇒φ¯s=φnormalsd+jφnormalsq=φs Taking into account this condition, the stator current expression is as follows:I¯s=φsLsLnormalmLnormalsI¯r Assuming that the electric network is balanced, and neglecting the stator resistance, which is a realistic assumption in the case of the high‐power generators, the stator voltage expression will be reduced as follows:V¯s=RsI¯s+dnormaldtφfalse¯normals+jωnormalsφfalse¯normals=jωnormalsφnormals=jVnormals where Vs is the voltage amplitude.…”
Section: Complex Power Control Of Dfigmentioning
confidence: 99%
See 1 more Smart Citation
“…The orientation condition is given by the following relation [1–5]:{1em4ptφnormalsd=φsφnormalsq=0false⇒φ¯s=φnormalsd+jφnormalsq=φs Taking into account this condition, the stator current expression is as follows:I¯s=φsLsLnormalmLnormalsI¯r Assuming that the electric network is balanced, and neglecting the stator resistance, which is a realistic assumption in the case of the high‐power generators, the stator voltage expression will be reduced as follows:V¯s=RsI¯s+dnormaldtφfalse¯normals+jωnormalsφfalse¯normals=jωnormalsφnormals=jVnormals where Vs is the voltage amplitude.…”
Section: Complex Power Control Of Dfigmentioning
confidence: 99%
“…Generally, the vector control strategy is widely employed to control the powers of DFIGs [3][4][5]. This control is usually based on the state model defined in the real domain of the generator.…”
Section: Introductionmentioning
confidence: 99%
“…Apart from the multiple control strategies available, this paper focusses on creating an independent PID controller for Q control. Results from [33] indicate that PID control of RES has better results than the control strategies available in use today.…”
Section: Implementation Of the Vvc Algorithmmentioning
confidence: 99%
“…The validated parameters of 7F Gas Turbine [16][17][18][19][20] used in the GGOV1 MATLAB /Simulink model, for implementing the model in the GE Control Systems Toolbox are listed in the following table:…”
Section: Parameter Validation For 7f Gas Turbinesmentioning
confidence: 99%
“…Provisions like implementation of droop control [11] through electrical power feedback, use of PI or PID controller in the controls of turbine governor (very common on modern gas turbine models) have effect on the transient stability. Active & reactive power regulation for turbines is nowadays provided through variable universe fuzzy controller (VUFC) [13], PI controllers & Direct Power Control [DPC] [18]. Therefore, modelling has to be carried out accordingly.…”
Section: Introductionmentioning
confidence: 99%