Active Damping Scheme for Leakage Current Reduction in Transformerless Three-Phase Grid-Connected PV Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
37
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(37 citation statements)
references
References 34 publications
0
37
0
Order By: Relevance
“…However, the CM current circuiting path within the inverter is a LC circuit, in which a LC resonance frequency f r exists. The CM current resonance suppression methods for inverter using the ILCL filter are proposed in [13,14] to reduce the leakage current injected to gird. In [14], the authors use a PI controller to control the CM current to be zero by real-time adjusting zero-sequence duty ratio in space vector modulation (SVM) technique.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the CM current circuiting path within the inverter is a LC circuit, in which a LC resonance frequency f r exists. The CM current resonance suppression methods for inverter using the ILCL filter are proposed in [13,14] to reduce the leakage current injected to gird. In [14], the authors use a PI controller to control the CM current to be zero by real-time adjusting zero-sequence duty ratio in space vector modulation (SVM) technique.…”
Section: Introductionmentioning
confidence: 99%
“…In [14], the authors use a PI controller to control the CM current to be zero by real-time adjusting zero-sequence duty ratio in space vector modulation (SVM) technique. In [13], the CM voltage which is injected into DM voltage to extend the inverter modulation index is controlled to suppression CM current resonance. Both the methods are useful and effective, and are based on a pair of small voltage vectors to adjust the CM voltage.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although this technique is simple and reliable it can lead to additional power losses which are undesirable especially in high power applications. Alternatively, active damping techniques which integrated into the control function are adopted as they do not cause additional power dissipation and meanwhile provide flexible resonance frequency suppression [10][11][12]. However, active methods are sensitive to parameter uncertainties and their controllability is limited by the sampling frequency of the adopted controller [13].…”
Section: Introductionmentioning
confidence: 99%
“…The robustness of control system is improved. This is avail to inhibit the resonance produced by LCL filter [15,16].…”
Section: Introductionmentioning
confidence: 99%