2021
DOI: 10.1155/2021/9925072
|View full text |Cite
|
Sign up to set email alerts
|

Active Disturbance Rejection Control for a Five-Level Cascaded H-Bridge Inverter Fed Induction Motor Sensorless Field-Oriented

Abstract: In this paper, a robust vector control sensorless based on three Active Disturbance Rejection Controllers (ADRC) for an induction motor fed by a five-level cascaded H-bridge was developed. The estimation of rotor position is achieved using a Luenberger estimator. The proposed model considers the disturbances and the inaccuracies of the system and compensates them using the extended state observer of ADRC. Moreover, a five-level cascaded H-bridge inverter is the best topology to minimize the torque ripples and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Compared to the traditional inverters, the use of MLIs in power circuits has many benefits, such as the reduction of THD, the reduction of stress across static switches, the reduction of power losses and filter volume, and the improvement of power factor with the increase of the voltage level [18]. There are generally three conventional categories of MLIs; the CHBMLI is the most commonly operated in industrial systems because of its high reliability, modularity, high-voltage capability, and power [3]. FLIs offer better performance than three-level and two-level inverters.…”
Section: Fl-hbci Topologymentioning
confidence: 99%
See 2 more Smart Citations
“…Compared to the traditional inverters, the use of MLIs in power circuits has many benefits, such as the reduction of THD, the reduction of stress across static switches, the reduction of power losses and filter volume, and the improvement of power factor with the increase of the voltage level [18]. There are generally three conventional categories of MLIs; the CHBMLI is the most commonly operated in industrial systems because of its high reliability, modularity, high-voltage capability, and power [3]. FLIs offer better performance than three-level and two-level inverters.…”
Section: Fl-hbci Topologymentioning
confidence: 99%
“…It is essential to note that the harmonic distortion in the current primarily stems from the characteristics of the inverter used in the system. In this context, the choice of inverter plays a crucial role in reducing current harmonics [3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation