2016
DOI: 10.1002/lary.26087
|View full text |Cite
|
Sign up to set email alerts
|

Active middle ear implant coupled bilaterally to the round window despite bilateral implanted stapes prostheses

Abstract: After stapes surgery, patients with mixed or moderate hearing loss have limited possibilities for hearing improvement. We are reporting on a patient who underwent stapedotomy bilaterally 20 years ago and had sensorineural and mixed hearing loss. Recurrent otitis externa prevented the use of hearing aids. This patient was treated bilaterally with the Vibrant Soundbridge (Med-El, Innsbruck, Austria) successively. The Schuknecht piston stapes prostheses remained in situ. The Floating Mass Transducer (FMT; Med-El)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

2
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(16 citation statements)
references
References 11 publications
2
14
0
Order By: Relevance
“…“Power-stapes”-surgery performed as SDT in conjunction with simultaneous or consecutive LP- or RW-vibroplasty for otosclerotic patients were previously reported in several case reports (4,1417). All authors concluded the intervention to be safe (4,1417).…”
mentioning
confidence: 97%
See 3 more Smart Citations
“…“Power-stapes”-surgery performed as SDT in conjunction with simultaneous or consecutive LP- or RW-vibroplasty for otosclerotic patients were previously reported in several case reports (4,1417). All authors concluded the intervention to be safe (4,1417).…”
mentioning
confidence: 97%
“…“Power-stapes”-surgery performed as SDT in conjunction with simultaneous or consecutive LP- or RW-vibroplasty for otosclerotic patients were previously reported in several case reports (4,1417). All authors concluded the intervention to be safe (4,1417). However, no case series exploring the significance of “power-stapes”-surgery in otosclerotic patients are available (4,1416).…”
mentioning
confidence: 97%
See 2 more Smart Citations
“…All patients have underwent a pure-tone audiometry hearing test that has determined pure-tone thresholds in the frequency range from 250 to 4000 Hz by air and bone conduction. Pure tone audiograms have been also performed after surgery reconstruction made by classical titanium ⋆ e-mail: r.rusinek@pollub.pl ⋆⋆ e-mail: marcinszym@poczta.onet.pl ⋆⋆⋆ e-mail: grzegorz.teresinski@umlub.pl prosthesis in [8], to estimate effects of different ossiculoplasty materials in [14] and to test the active middle ear implant [15]. Bony ankylosis hydroxyapatite prostheses in the middle ear have been presented in [11] but without any experimental verification.…”
Section: Introductionmentioning
confidence: 99%