2015 American Control Conference (ACC) 2015
DOI: 10.1109/acc.2015.7171055
|View full text |Cite
|
Sign up to set email alerts
|

Active vibration isolation control: Comparison of feedback and feedforward control strategies applied to Coriolis mass-flow meters

Abstract: Abstract-In this paper we describe the design, implementation and results of multi degree of freedom (DOF) active vibration control for a Coriolis mass-flow meter (CMFM). Without vibration control, environmental vibrational disturbances results in nanometre movement of the fluid-conveying tube which causes erroneous mass-flow measurements. In order to reduce the transmissibility from external vibrations to the internal tube displacement active vibration control is applied.A comparison of a feedback control str… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…Compared to feedback control, the advantages of feedforward control are two-fold. First, it often leads to better signal-to-noise ratios because the measured disturbance signals are not (mechanically) low-pass filtered by the passive vibration isolator itself [11]. Second, feedforward control does not affect the closed-loop stability properties, whereas highgain feedback control requires a high bandwidth that can lead to stability problems.…”
Section: Introductionmentioning
confidence: 99%
“…Compared to feedback control, the advantages of feedforward control are two-fold. First, it often leads to better signal-to-noise ratios because the measured disturbance signals are not (mechanically) low-pass filtered by the passive vibration isolator itself [11]. Second, feedforward control does not affect the closed-loop stability properties, whereas highgain feedback control requires a high bandwidth that can lead to stability problems.…”
Section: Introductionmentioning
confidence: 99%
“…These strategies are compared on the ability to reduce the influence of external vibrations on the mass-flow measurement value. Several advances are made on previous work [6,21,22] : (i) the feed-forward strategy is extended to Multiple-Input-Multiple-Output (MIMO), (ii) the influence of the sensor noise levels is included in the analysis and (iii) the systems performance is validated for 3D disturbances.…”
Section: Introductionmentioning
confidence: 99%
“…These strategies are compared on the ability to reduce the influence of external vibrations on the mass-flow measurement value. Several advances are made on previous work [70,74,59]: (i) the feedforward strat- egy is extended to Multiple-Input-Multiple-Output (MIMO), (ii) the influence of the sensor noise levels is included in the analysis and (iii) the systems performance is validated for 3D disturbances.…”
Section: Introductionmentioning