2007
DOI: 10.1159/000098714
|View full text |Cite
|
Sign up to set email alerts
|

Acute Recurrent Polyhydramnios: A Combination of Amniocenteses and NSAID May Be Curative Rather than Palliative

Abstract: Acute recurrent polyhydramnios is a rare occurrence characterized by a poor fetal outcome. This is a case report describing a 34-year-old woman presenting with acute recurrent polyhydramnios. Treatment with non-steroidal anti-inflammatory drugs (NSAID) and therapeutic amniocenteses was initiated immediately and resulted in a decreased amniotic fluid production from 30 weeks’ gestation. Even after the discontinuation of NSAID treatment, the amniotic fluid production normalized, and the woman delivered a healthy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 24 publications
0
1
1
Order By: Relevance
“…De Santis et al put forward hypothesis of acute recurrence of polyhydramnios may be linked to the dysfunctional chorionic receptors for prolactin. Previous study assessed AF prolactin levels three times during the pregnancy, study revealed no change with advancing gestational age (27). No change was determined in this study, however intervals that the samples were obtained too short to detect decreasing concentrations with advancing gestational age.…”
Section: Discussioncontrasting
confidence: 52%
“…De Santis et al put forward hypothesis of acute recurrence of polyhydramnios may be linked to the dysfunctional chorionic receptors for prolactin. Previous study assessed AF prolactin levels three times during the pregnancy, study revealed no change with advancing gestational age (27). No change was determined in this study, however intervals that the samples were obtained too short to detect decreasing concentrations with advancing gestational age.…”
Section: Discussioncontrasting
confidence: 52%
“…However, there is no consensus regarding the volume of aspirated amniotic fluid, the speed of aspiration and the use of tocolytics or antibiotics. The intervention is usually concluded when ultrasound examination shows an AFI of 15 to 20 cm or if intra-amniotic pressure drops to < 20 mmHg [53,66]. In some cases, the intervention had to be terminated due to maternal discomfort or premature placental abruption.…”
Section: Amnioreductionmentioning
confidence: 99%