2021
DOI: 10.1051/sicotj/2021056
|View full text |Cite
|
Sign up to set email alerts
|

ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures

Abstract: Introduction: In recent years, computer-assisted surgery has made it possible to undergo surgery with a high degree of precision. This study aimed to investigate the usefulness of computer-assisted surgery for femoral trochanteric fractures using the ADAPT (ADAptive Positioning Technology) system. Methods: A total of forty patients with femoral trochanteric fracture underwent intramedullary nailing for fracture fixation: in twenty patients, the ADAPT system (ADAPT group), and in the other twenty, it was not us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 21 publications
0
5
1
Order By: Relevance
“…Thereby surgeons answered that ADAPT was “unnecessarily time consuming”, and “increasing fluoroscopy use”. Contrary to our findings, Murakami et al report significantly shorter surgical procedure time ( p < 0.05) and reduced intraoperative fluoroscopy ( p < 0.01) when using ADAPT ( n = 20) compared without ADAPT ( n = 20) [ 16 ]. This is remarkable, but may partly be explained by the fact that a trained computer operator was present for all ADAPT-procedures.…”
Section: Discussioncontrasting
confidence: 99%
“…Thereby surgeons answered that ADAPT was “unnecessarily time consuming”, and “increasing fluoroscopy use”. Contrary to our findings, Murakami et al report significantly shorter surgical procedure time ( p < 0.05) and reduced intraoperative fluoroscopy ( p < 0.01) when using ADAPT ( n = 20) compared without ADAPT ( n = 20) [ 16 ]. This is remarkable, but may partly be explained by the fact that a trained computer operator was present for all ADAPT-procedures.…”
Section: Discussioncontrasting
confidence: 99%
“…New technologies have been invented to optimize the femoral neck-cannulated screw-inserted procedure. From the rst generation, represented by instrument-positioning device [10][11][12] , to the second generation, represented by optical navigation technology of orthopedic surgical robot [4,13,14] , they provide substantial help in orthopedic surgical navigation. However, they have the following drawbacks: cumbersome operation, expensive equipment, inaccuracy, and more radiation exposure (Table 4).…”
Section: Discussionmentioning
confidence: 99%
“…Benjamin Moulin [17] 2019 Murakami [19] intertrochanteric fracture patients system based on Carm machine min min Sizhe Wang [22] 2021 Femoral intertrochanteric fracture patients 3D-Printed Navigation Template 3.04± 0.39mm 93.3% --…”
Section: 3min 200smentioning
confidence: 99%
“…New technologies have been invented to optimize the femoral neck-cannulated screw-inserted procedure. From the first generation, represented by instrument-positioning device [ 10 12 ], to the second generation, represented by optical navigation technology of orthopedic surgical robot [ 4 , 13 – 20 ], they provide substantial help in orthopedic surgical navigation. However, they have the following drawbacks: cumbersome operation, expensive equipment, inaccuracy, and more radiation exposure (Table 4 ).…”
Section: Discussionmentioning
confidence: 99%