Adaptation of Coenzyme Stimulation Assays for the Nutritional Assessment of Vitamins B1, B2 and B6 Using the Cobas Bio Centrifugal Analyser

Abstract: Adaptation of coenzyme stimulation assays for the nutritional assessment of thiamine, riboflavin and pyridoxine on the Cobas Bio centrifugal analyser are described. Whole blood was collected into acid-citrate dextrose, which preserves the erythrocytes, prior to assay for several days. Washed erythrocytes stored at −70°C and subsequently thawed, showed altered enzyme activities. The methods offer improved precision over existing procedures and take advantage of the high throughput capabilities of the instrument… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

1994
1994
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(17 citation statements)
references
References 8 publications
0
17
0
Order By: Relevance
“…Enzymatic methods are affected by preparation of hemolysates (8) and by storage (5,52) and concentrations of substrates and cofactors (35). These factors lead to a notable analytical variation between laboratories.…”
Section: Methodological Issuesmentioning
confidence: 99%
See 1 more Smart Citation
“…Enzymatic methods are affected by preparation of hemolysates (8) and by storage (5,52) and concentrations of substrates and cofactors (35). These factors lead to a notable analytical variation between laboratories.…”
Section: Methodological Issuesmentioning
confidence: 99%
“…The corresponding values for E-GRAC were 1.20 (31) and 1.68 (52) and for 5ASTAC 1.80 (82) and 2.47 (27). Ideally, each laboratory should make its own reference interval or should ascertain that the chosen reference interval is made by precisely comparable methods.…”
Section: Methodological Issuesmentioning
confidence: 99%
“…Measurement of EASTAC (Mount et al, 1987) and EGRAC (Powers et al, 1983) were by enzyme assay on the Cobas Fara centrifugal analyzer (Roche Diagnostics, Welwyn Garden City, UK). For all assays, samples were analysed blind, in duplicate (except for EGRAC where triplicate samples were measured), and within 6 months after sampling.…”
Section: Laboratory Measurementsmentioning
confidence: 99%
“…Plasma total homocysteine was measured by Abbott Imx FPIA (Leino, 1999). Erythrocyte aspartate aminotransferase activation coefficient (index of vitamin B 6 status) and erythrocyte glutathione reductase activation coefficient (index of riboflavin status) were measured by enzyme assay on the Cobas Fara centrifugal analyser (Roche Diagnostics, Welwyn Garden City, UK) according to the procedure of Mount et al (1987). Plasma pyridoxal phosphate was determined by HPLC using fluorescent detection (Bates et al, 1999).…”
Section: Methodsmentioning
confidence: 99%