2014
DOI: 10.1016/j.bspc.2013.10.004
|View full text |Cite
|
Sign up to set email alerts
|

Adaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
23
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(23 citation statements)
references
References 23 publications
0
23
0
Order By: Relevance
“…In this section, the parameters of WFLC, BMFLC, ASBMFLC [14] and ABPF are tuned to fit the tremulous signals as well as possible in order to fairly compare their performance. In the proposed method, different lengths of data vector lead to different time delays for starting adapting frequency and different estimated frequency errors between the estimated frequency and the actual frequency in the stabilization stage.…”
Section: B Determination the Values Of Algorithms Parametersmentioning
confidence: 99%
See 3 more Smart Citations
“…In this section, the parameters of WFLC, BMFLC, ASBMFLC [14] and ABPF are tuned to fit the tremulous signals as well as possible in order to fairly compare their performance. In the proposed method, different lengths of data vector lead to different time delays for starting adapting frequency and different estimated frequency errors between the estimated frequency and the actual frequency in the stabilization stage.…”
Section: B Determination the Values Of Algorithms Parametersmentioning
confidence: 99%
“…The swing is employed to simulate tremor movement and the low-speed and high range swing of the cantilever realized by artificial pull through the rope mimics the voluntary movement. The rotation angle of cantilever is measured by the photoelectric encoder, HEDSS ISC3806 and the data reveals that the platform could generate suitable tremor with intentional movements [14].…”
Section: A Experiments and Data Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…BMFLC is designed to track multiple harmonics of a signal [29][30][31] and showed higher accuracy compared to conventional FLC-based filters [30]. In the literature, BMFLC filtering has also been used for extracting physiological hand tremor of surgeons [36][37][38] and recently has shown good performance in extracting pathological involuntary motions [33]. .…”
Section: Components and The Design Of Actionsmentioning
confidence: 99%