Additively manufactured cryogenic microchannel distillation device for air separation

Abstract: The efficiency of air separation is tested using three different small-scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate-type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar condition… Show more