2018
DOI: 10.1101/373977
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Addressing challenges of high spatial resolution, UHF field fMRI for group analysis of higher-order cognitive tasks; an inter-sensory task directing attention between visual and somatosensory domains

Abstract: Abstract:Functional MRI at ultra-high field (UHF, ≥7T) provides significant increases in BOLD contrast-to-noise ratio (CNR) compared with conventional field strength (3T), and has been exploited for reduced field-of-view, high spatial resolution mapping of primary sensory areas. Applying these high spatial resolution methods to investigate whole brain functional responses to higher-order cognitive tasks leads to a number of challenges, in particular how to perform robust group-level statistical analyses.This s… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 77 publications
(116 reference statements)
0
1
0
Order By: Relevance
“…Our EEG results are corroborated by a separate, high resolution fMRI study conducted by our group at ultra-high field (7T) on a sub-sample of the same subjects (7/10 participants also performed Experiment 1), using the same multi-modal task as in Experiment 1. This study (Aquino et al, 2018) also reveals two fMRI sources modulated by attention: i) quadratic BOLD-response modulations over parietal areas when contrasting attentional effort (100 vs. 60%) and ii) linear modulations over visual areas when contrasting the location of attention (100 vs. 100%). Due to the superior spatial resolution of fMRI, these results strongly suggest that the two alpha band sources measured with EEG are indeed distinct sources which need to be considered separately.…”
Section: Functional Significancementioning
confidence: 56%
“…Our EEG results are corroborated by a separate, high resolution fMRI study conducted by our group at ultra-high field (7T) on a sub-sample of the same subjects (7/10 participants also performed Experiment 1), using the same multi-modal task as in Experiment 1. This study (Aquino et al, 2018) also reveals two fMRI sources modulated by attention: i) quadratic BOLD-response modulations over parietal areas when contrasting attentional effort (100 vs. 60%) and ii) linear modulations over visual areas when contrasting the location of attention (100 vs. 100%). Due to the superior spatial resolution of fMRI, these results strongly suggest that the two alpha band sources measured with EEG are indeed distinct sources which need to be considered separately.…”
Section: Functional Significancementioning
confidence: 56%