2002
DOI: 10.1002/1615-9314(20020801)25:12<759::aid-jssc760>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

Adduct formation in electrospray ionization. Part 1: Common acidic pharmaceuticals

Abstract: This study focuses on pseudo-molecular ion formation in electrospray ionization mass spectrometry (ESI-MS) of six anti-inflammatory pharmaceuticals with similar functionality. The formation of particular pseudo-molecular ions depends on ion affinity and molecular structure of the analyte as well as the solvent/buffer conditions used. Six common anti-inflammatory agents are mixed 1:1 with six different acetonitrile/aqueous buffer solutions at varying concentrations. The analytes are ibuprofen, carprofen, naprox… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
60
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 74 publications
(60 citation statements)
references
References 20 publications
0
60
0
Order By: Relevance
“…Indeed, the Enke group observed electrospray response to correlate linearly with the nonpolar surface area of small peptides, which was taken as a measure of surface activity [22]. More recently, several investigations of small acidic molecules have shown a correlation between electrospray response in the negative ion mode and partition coefficient between octanol and water (logP) [23,24], a measure of analyte polarity. Because computations with molecular modeling software can easily be used to calculate logP from analyte structure, this relationship is a useful one.…”
Section: Surface Activity and Electrospray Responsementioning
confidence: 99%
“…Indeed, the Enke group observed electrospray response to correlate linearly with the nonpolar surface area of small peptides, which was taken as a measure of surface activity [22]. More recently, several investigations of small acidic molecules have shown a correlation between electrospray response in the negative ion mode and partition coefficient between octanol and water (logP) [23,24], a measure of analyte polarity. Because computations with molecular modeling software can easily be used to calculate logP from analyte structure, this relationship is a useful one.…”
Section: Surface Activity and Electrospray Responsementioning
confidence: 99%
“…Unfortunately, many common oxygen-containing compounds, including carboxylic acids, do not produce stable protonated molecules when ionized by the commonly employed positive-mode ESI. Hence, such compounds have been generally analyzed using negative-mode ESI due to their acidic nature [33][34][35]. Regrettably, the majority of this past work provides no structural information that would allow, for example, the differentiation of isomers.…”
Section: Introductionmentioning
confidence: 99%
“…However, the general order of the ion intensities from the deprotonated amides was found to be in good agreement with expected acidity based on resonance effects in aromatic substitution. Schug and McNair compared the negative ionization response of six ibuprofen analogs of similar acidity (pKa values of 4.14 to 4.41) under various solvent conditions [12]. The preference to form cluster ions was found to be related to the structure and properties (such as polarity and nature of substituents) of the individual compounds.…”
mentioning
confidence: 99%