1995
DOI: 10.1016/0109-5641(95)80046-8
|View full text |Cite
|
Sign up to set email alerts
|

Adhesion testing of dentin bonding agents: A review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
277
2
103

Year Published

2007
2007
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 468 publications
(422 citation statements)
references
References 41 publications
10
277
2
103
Order By: Relevance
“…Smaller specimens contain a lower number of initial defects and have more homogeneous stress distributions; hence, bond strengths as well as adhesive failure between the adhesive and dentin can be examined more accurately. This phenomenon reflects the characteristics of the microtensile test, resulting from stress concentration at the bonded interface (21). Bond strength values can be used for comparing the effectiveness of bonding systems; however, they cannot be related directly to what might happen clinically.…”
Section: Discussionmentioning
confidence: 99%
“…Smaller specimens contain a lower number of initial defects and have more homogeneous stress distributions; hence, bond strengths as well as adhesive failure between the adhesive and dentin can be examined more accurately. This phenomenon reflects the characteristics of the microtensile test, resulting from stress concentration at the bonded interface (21). Bond strength values can be used for comparing the effectiveness of bonding systems; however, they cannot be related directly to what might happen clinically.…”
Section: Discussionmentioning
confidence: 99%
“…Para avaliar o comportamento e a qualidade destes novos materiais, vários testes têm sido desenvolvidos (PASHLEY et al, 1995;PASHLEY et al, 1999;SANO et al, 1994) envolvendo tanto esmalte quanto dentina, em dentes decíduos e Em dentes normais, observa-se grande variação nos valores de resistência de união constatados tanto pelo ensaio de cisalhamento como pelo de tração (BIANCHI, 1999 VAN NOORT et al, 1989).…”
Section: Testes Mecânicos Usados Para Avaliar a Resistência De União unclassified
“…BRAGA; CARRILHO, 1998;SCHREINER et al, 1998;VAN NOORT et al, 1989), tem-se preconizado, com sucesso, o teste de microtração (ABDALLA, 2004;ARMSTRONG et al, 2003;KANEMURA;TAGAMI, 1999;PASHLEY et al, 1995;SANO et al, 1994;SCHREINER et al, 1998). Apesar de também apresentar algumas desvantagens como dificuldade técnica, trabalho laboratorial excessivo, dificuldade de mensurar valores menores que 5 MPa, requerer o uso de equipamentos especiais e causar rápida desidratação dos espécimes devido ao tamanho reduzido (PASHLEY et al, 1995), este ensaio apresenta importantes vantagens como obtenção de múltiplos espécimes a partir do menor número de dentes, ao se conseguir o seu preparo adequado, domínio do procedimento experimental e uso de equipamentos precisos, o que possibilita a redução da variabilidade da amostra.…”
Section: Frente a Essas Desvantagens E Críticas De Vários Autores (Caunclassified
See 2 more Smart Citations