2022
DOI: 10.1016/j.phro.2022.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Adoption of respiratory motion management in radiation therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 49 publications
0
9
0
Order By: Relevance
“…Narrowing the gating window of the fiducial marker increased the treatment time, whereas widening the gating window increased the risk of unplanned irradiation. Therefore, we believe that the gating window should not be fixed and that the lung tumor and individual markers should be preliminarily evaluated using 4DCT or other methods for individual patients [16] . In actual treatment, multiple fiducial markers are often implanted, and we believe that selecting an appropriate fiducial marker among all markers with few amplitude differences, in advance, can help avoid unplanned irradiation.…”
Section: Discussionmentioning
confidence: 99%
“…Narrowing the gating window of the fiducial marker increased the treatment time, whereas widening the gating window increased the risk of unplanned irradiation. Therefore, we believe that the gating window should not be fixed and that the lung tumor and individual markers should be preliminarily evaluated using 4DCT or other methods for individual patients [16] . In actual treatment, multiple fiducial markers are often implanted, and we believe that selecting an appropriate fiducial marker among all markers with few amplitude differences, in advance, can help avoid unplanned irradiation.…”
Section: Discussionmentioning
confidence: 99%
“…The increasing use of SABR has gone hand‐in‐hand with technical improvements. Burton et al 35 . show that motion managed treatments now most often include the use of 4DCT and VMAT.…”
Section: Discussionmentioning
confidence: 99%
“…The increasing use of SABR has gone hand-in-hand with technical improvements. Burton et al 35 show that motion managed treatments now most often include the use of 4DCT and VMAT. This agrees with our results which additionally show that SGRT is becoming more prominent.…”
Section: Staffing For Treatmentmentioning
confidence: 99%
“…A1; Table A1 ) and previous reports of those workshops [2] , [3] , [4] , [5] , [6] , [7] . The content of these meetings, surveys and guidelines [8] , [9] , [37] , [38] , [39] , [40] , [41] , [42] , [43] and relevant articles in the field of 4D PT, mainly published within the last 3 years, built the scientific basis for identifying the way towards clinical implementation of selected motion management and 4D treatment strategies. The literature review was based on a PubMed search (status September 2023).…”
Section: Methodsmentioning
confidence: 99%
“…As an example, the ARPANSA and TG324 photon surveys showed that passive respiratory motion management with the ITV concept was more widely used than active methods [40] , [41] . Following the AAPM Task Groups TG76 and TG324 survey on motion management for photon therapy [41] , [43] , the AAPM Task Group report 290 focused exclusively on 4D PT [38] .…”
Section: Clinical Implementations Of 4d Pt Treatments Based On Intern...mentioning
confidence: 99%