2018
DOI: 10.1016/j.molliq.2018.01.079
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption kinetics of lysozyme on multi-walled carbon nanotubes and amino functionalized multi-walled carbon nanotubes from aqueous solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 47 publications
0
4
0
Order By: Relevance
“…The value of the second rate constant of the adsorption process (k 2 ) 6.92 × 10 −5 g mg −1 min −1 obtained assuming the model of pseudo-second order proves that the process of adsorption is much faster than of DOX adsorption on the carrier modified by Wang [43] (3.52 × 10 −8 g mg −1 min −1 ), however, it is much slower than that of adsorption of lysozyme [65] or curcumin [55] on MWCNTs modified in different ways.…”
Section: Kinetic Model Parameters Valuesmentioning
confidence: 73%
“…The value of the second rate constant of the adsorption process (k 2 ) 6.92 × 10 −5 g mg −1 min −1 obtained assuming the model of pseudo-second order proves that the process of adsorption is much faster than of DOX adsorption on the carrier modified by Wang [43] (3.52 × 10 −8 g mg −1 min −1 ), however, it is much slower than that of adsorption of lysozyme [65] or curcumin [55] on MWCNTs modified in different ways.…”
Section: Kinetic Model Parameters Valuesmentioning
confidence: 73%
“…Therefore, understanding the adsorption process is critical to control, predict, and manipulate protein adsorption to design suitable membranes to yield intended applications. Protein adsorption has been thoroughly studied in the last two decades . Nevertheless, it is difficult to predict the interaction at the interfaces between proteins and polymeric particles for several reasons including the large size of proteins molecules compared to particles of the polymeric membrane.…”
Section: Introductionmentioning
confidence: 99%
“…Subsequently, the concentration of collected water (unbound peptides) ( C 1 ) was determined according to the standard curve at 238 nm by the microplate reader (Epoch 2, BioTek, USA). Last, the amount of peptide on 1 mg of MWNTs was calculated according to eq where C 0 are the concentrations of peptides at the initial time, and m is the mass of the MWNTs used. Measurements were repeated six times.…”
Section: Methodsmentioning
confidence: 99%