1998
DOI: 10.1007/s002590050304
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

Abstract: Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administere… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
9
1

Year Published

2001
2001
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 2 publications
0
9
1
Order By: Relevance
“…The residual doses that we observed here were on average lower than those for 99m Tc-sestamibi that were observed in the MILLISIEVERT study, in which residual activity for a similar ULD injection averaged 64 MBq and ranged from 6.3 to 144 MBq (9). Although limited data suggest that tetrofosmin may be less adsorptive than some other 99m Tc-based radiopharmaceuticals (22), numerous factors influence 99m Tc residual activity, including not just the particular radiopharmaceutical but also the type of syringe and length of time the radiopharmaceutical is in the syringe before injection (23,24). The determinants of residual activity for ULD injections is a subject that requires further study.…”
Section: Discussioncontrasting
confidence: 68%
“…The residual doses that we observed here were on average lower than those for 99m Tc-sestamibi that were observed in the MILLISIEVERT study, in which residual activity for a similar ULD injection averaged 64 MBq and ranged from 6.3 to 144 MBq (9). Although limited data suggest that tetrofosmin may be less adsorptive than some other 99m Tc-based radiopharmaceuticals (22), numerous factors influence 99m Tc residual activity, including not just the particular radiopharmaceutical but also the type of syringe and length of time the radiopharmaceutical is in the syringe before injection (23,24). The determinants of residual activity for ULD injections is a subject that requires further study.…”
Section: Discussioncontrasting
confidence: 68%
“…Several authors report that, in their hands, the adsorption of a substantial number of tracers to the syringe was below 3-4%, which was seemingly not affected by the syringe brand [3,4]. Several authors report that, in their hands, the adsorption of a substantial number of tracers to the syringe was below 3-4%, which was seemingly not affected by the syringe brand [3,4].…”
mentioning
confidence: 99%
“…The adsorption behavior of some radiopharmaceuticals on glass vials has been studied (3,4). The adsorption of 99m Tc-methylene diphosphonate, 99m Tc-sestamibi, 99m Tc-tetrofosmin, 99m Tc-furifosmin, and 99m Tc-macroaggregated albumin on plastic syringes has also been reported (5,6).…”
mentioning
confidence: 99%