2013
DOI: 10.1016/j.colsurfb.2013.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Adsorptive stripping voltammetry determination of methyldopa on the surface of a carboxylated multiwall carbon nanotubes modified glassy carbon electrode in biological and pharmaceutical samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 28 publications
(13 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…The regression equations are Ip (µA) = 0.0289  (mV s -1 ) + 2.184 (R= 0.996) for CPE and Ip (µA) = 0.1019  (mV s -1 ) + 8.956 (R=0.995) for In2O3 NPs/CPE. Such behavior suggests that the oxidation of FMT at CPE and In2O3 NPs/CPE is a typical adsorption-controlled electrode process [39,40].…”
Section: Electrochemical Behavior Of Fmt On Cpe and Modified In2o3 Npmentioning
confidence: 97%
“…The regression equations are Ip (µA) = 0.0289  (mV s -1 ) + 2.184 (R= 0.996) for CPE and Ip (µA) = 0.1019  (mV s -1 ) + 8.956 (R=0.995) for In2O3 NPs/CPE. Such behavior suggests that the oxidation of FMT at CPE and In2O3 NPs/CPE is a typical adsorption-controlled electrode process [39,40].…”
Section: Electrochemical Behavior Of Fmt On Cpe and Modified In2o3 Npmentioning
confidence: 97%
“…On the other hand, analytical methods based on voltammetric stripping techniques have been recently benefited from the unique properties of CNT modified electrodes 29. A stronger adsorption of many organic compounds on CNTs in comparison with conventional electrode materials has been recently used for the determination of quercetin 30, 31 paracetamol 32, antiretroviral drug Abacavir 33, 4‐hexylresorcinol 34 or methyldopa 35. Thus, in this paper it is reported the application of COOH functionalized MWCNT modified SPCEs for the detection of uric acid by adsorptive voltammetry.…”
Section: Introductionmentioning
confidence: 99%
“…Of the techniques used in several procedures most are based on kinetic measurements (James;Hoo;William, 2006), highperformance liquid chromatography (Bahrami, Kiani, Mirzaeei, 2006;Muzzi et al, 2008;Li et al, 2010), voltammetry (Rezaei, Askarpour, Ensafi, 2013), spectrophotometry (Gadkariem et al, 2009;Brasil, 2010;Matos,Silva;Ribeiro, 2012; and diffuse reflectance spectroscopy (Ribeiro, Pezza, Pezza, 2006).…”
Section: Introductionmentioning