2011 64th Annual Conference for Protective Relay Engineers 2011
DOI: 10.1109/cpre.2011.6035625
|View full text |Cite
|
Sign up to set email alerts
|

Advanced bus transfer and load shedding applications with IEC61850

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 1 publication
1
10
0
Order By: Relevance
“…In [6][7][8], the authors discussed the need for a fast and reliable LS scheme capable of detecting underfrequency (UF) or UV events that may be present during dangerous system overloading conditions. A GOOSE messagingbased LS scheme is proposed for radial feeders on a main-tie-main line-bus configuration when the tie breaker is open.…”
Section: A Review Of Iec 61850-based Idlsmentioning
confidence: 99%
See 2 more Smart Citations
“…In [6][7][8], the authors discussed the need for a fast and reliable LS scheme capable of detecting underfrequency (UF) or UV events that may be present during dangerous system overloading conditions. A GOOSE messagingbased LS scheme is proposed for radial feeders on a main-tie-main line-bus configuration when the tie breaker is open.…”
Section: A Review Of Iec 61850-based Idlsmentioning
confidence: 99%
“…GOOSE messaging is used between the feeder and main source relays to exchange load flow, voltage, and frequency values and to initiate commands for opening/closing feeder breakers. The scheme proposed in [6][7][8] suggests using the source relay to detect UV or UF conditions and initiating LS on preselected configuration and priority levels.…”
Section: A Review Of Iec 61850-based Idlsmentioning
confidence: 99%
See 1 more Smart Citation
“…Other studies [17,18] went beyond an abstract discussion and outlined important IEC 61850-related concepts such as scheme redundancy and sending/receiving IEC 61850 GOOSE data items. Special focus was given to the residual voltage transfer scheme (RVTS) and a comparison of traditional three-relay setups.…”
Section: A Review Of Iec 61850-based Btssmentioning
confidence: 99%
“…These examples and applications show that an Ethernet based standard such as IEC 61850 can be used for protection, command and control, and SCADA gathering of data over the same redundant wire pair [8][9][10][11]. As this "real time" data is provided to the central controller or SCADA master in the system graphics can be populated to alert engineers and operations to system status [3,6].…”
Section: Industrial and Commercial Power Systems Justificationmentioning
confidence: 99%