IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics 2006
DOI: 10.1109/iecon.2006.347807
|View full text |Cite
|
Sign up to set email alerts
|

Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
254
0
11

Year Published

2006
2006
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 368 publications
(265 citation statements)
references
References 10 publications
0
254
0
11
Order By: Relevance
“…The 2nd-order harmonic in the positive sequence component caused by the negative sequence component can be eliminated by cross decoupling. The decoupling network can eliminate harmonics from both the positive and negative sequence components [18]. Compared with the SRF-PLL, the DDSRF-PLL does not have to reduce the bandwidth in order to eliminate the influence of negative sequence components.…”
Section: A Decoupled Double Synchronous Reference Frame Pllmentioning
confidence: 99%
“…The 2nd-order harmonic in the positive sequence component caused by the negative sequence component can be eliminated by cross decoupling. The decoupling network can eliminate harmonics from both the positive and negative sequence components [18]. Compared with the SRF-PLL, the DDSRF-PLL does not have to reduce the bandwidth in order to eliminate the influence of negative sequence components.…”
Section: A Decoupled Double Synchronous Reference Frame Pllmentioning
confidence: 99%
“…4 illustrates the DSOGI-FLL structure. Further details about DSOGI-FLL can be obtained from [7], [8]. Performance comparison between SRF-PLL and DSOGI-FLL will be presented through the simulation.…”
Section: B Dsogi-fll Synchronizationmentioning
confidence: 99%
“…Dual Second Order Generalized Integrator, DSOGI based Frequency Locked Loop, DSOGI-FLL is an insensitive frequency-adaptive synchronization mechanism which benefits the instantaneous symmetrical component analysis considering adaptive filters [7]. Being frequency-based, DSOGI-FLL can efficiently ride-through the grid perturbations, provides a clean synchronization signal and attenuates grid voltage high-frequency components [8]. Fig.…”
Section: B Dsogi-fll Synchronizationmentioning
confidence: 99%
“…As for a weak grid, there may be larger grid-frequency fluctuation such that a big error would be the result. As for sinusoidal signal, a SOGI [12,13] can be configured as a frequency-adaptive band-pass filter and QSG by using feedback from the output signal. The resulting structure is shown in …”
Section: Principle Of the Grid Virtual Flux Estimationmentioning
confidence: 99%
“…The decoupled double synchronous reference frame PLL (DDSRF-PLL) [10] can detect fundamental negative-sequence components or the specified harmonic components, but when the DDSRF-PLL is extended in multiple reference frames, decoupling cells would be very complicated because feedback decoupling of each component uses a rotation transformation. Some scholars use the optimal iterative method with symmetrical components and state-space filter to approach the input signal [11,12]. Rodriguez et al proposed a second-order generalized integrator-frequency-locked loop (SOGI-FLL) that makes improvements from an enhanced phase-locked loop by using the SOGI as the quadrature signal generator (QSG).…”
Section: Introductionmentioning
confidence: 99%