2012
DOI: 10.1016/j.solener.2011.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Advanced solar assisted desiccant and evaporative cooling system equipped with wet heat exchangers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(14 citation statements)
references
References 7 publications
0
13
0
1
Order By: Relevance
“…Finocchiaro et al [75] observed that because of the limited cooling capacity of the return air in a desiccant cooling system, the obtained outlet temperature was hardly lower than 26 • C. So, to avoid this problem, a packed wet heat exchanger was used as a replacement for the sensible heat exchanger for removal of more sensible load. An experimental setup was developed for studying the detailed performance of the proposed hybrid SADDCS.…”
Section: Recent Advancements In the Field Of Desiccant Cooling Systemsmentioning
confidence: 99%
“…Finocchiaro et al [75] observed that because of the limited cooling capacity of the return air in a desiccant cooling system, the obtained outlet temperature was hardly lower than 26 • C. So, to avoid this problem, a packed wet heat exchanger was used as a replacement for the sensible heat exchanger for removal of more sensible load. An experimental setup was developed for studying the detailed performance of the proposed hybrid SADDCS.…”
Section: Recent Advancements In the Field Of Desiccant Cooling Systemsmentioning
confidence: 99%
“…So kann bspw. die Adsorption isotherm geführt werden oder Wärme aus dem entfeuchteten Luftstrom genutzt werden, um die Abluft für die Regeneration des Adsorbens vorzuheizen .…”
Section: Stand Der Forschungunclassified
“…Typical mean values of the previous configurations ranged from 2 to 2.9 [19]. Due to the increased cooling performances, the electrical COP of the system, built by Finocchiaro [9], was clearly improved reaching 4.6. The mean value of the current thermal COP ranges from 1.3 to 1.6, while in a previous study [7], the value recorded 0.75, and in another one, the value reached 1.8 [9].…”
Section: Coefficient Of Performance Copmentioning
confidence: 99%
“…Due to the increased cooling performances, the electrical COP of the system, built by Finocchiaro [9], was clearly improved reaching 4.6. The mean value of the current thermal COP ranges from 1.3 to 1.6, while in a previous study [7], the value recorded 0.75, and in another one, the value reached 1.8 [9]. Figure 5 shows a comparison of the system energy consumptions of the LDACS and the package conventional system under the condition of operating the system for 8 hours.…”
Section: Coefficient Of Performance Copmentioning
confidence: 99%
See 1 more Smart Citation