2023
DOI: 10.3892/ol.2023.13697
|View full text |Cite
|
Sign up to set email alerts
|

Advances in automatic delineation of target volume and cardiac substructure in breast cancer radiotherapy (Review)

Abstract: Postoperative adjuvant radiotherapy plays an important role in the treatment of patients with breast cancer. With the continuous development of radiotherapeutic technologies, the requirements for radiotherapeutic accuracy are increasingly high. The accuracy of target volume and organ at risk delineation significantly affects the effect of radiotherapy. Automatic delineation software has been continuously developed for the automatic delineation of target areas and organs at risk. Automatic segmentation based on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(1 citation statement)
references
References 81 publications
0
1
0
Order By: Relevance
“…Several models have been frequently used for the AI contouring of OAR and assessing clinical target volumes (CTVs). Convolutional neural networks (CNN) with a U-Net architecture 6 have been shown to have a dice similarity coefficient (DSC) of greater than 0.80 on average while segmenting organs such as the heart, lungs, esophagus, and spinal cord. 5 Autosegmentation software Workflow Box, Embrace CT , and DLC Expert offer a DSC of 0.95 for the whole heart and 0.80 for the four cardiac chambers 7 ; 0.96 for the heart, 0.98 for the lungs, and 0.82 for the spinal cord 8 ; and 0.96 for the heart, 0.98 for the lungs, and 0.86 for the spinal cord, 8 respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Several models have been frequently used for the AI contouring of OAR and assessing clinical target volumes (CTVs). Convolutional neural networks (CNN) with a U-Net architecture 6 have been shown to have a dice similarity coefficient (DSC) of greater than 0.80 on average while segmenting organs such as the heart, lungs, esophagus, and spinal cord. 5 Autosegmentation software Workflow Box, Embrace CT , and DLC Expert offer a DSC of 0.95 for the whole heart and 0.80 for the four cardiac chambers 7 ; 0.96 for the heart, 0.98 for the lungs, and 0.82 for the spinal cord 8 ; and 0.96 for the heart, 0.98 for the lungs, and 0.86 for the spinal cord, 8 respectively.…”
Section: Introductionmentioning
confidence: 99%