Advances in heterostructured scintillators: toward a new generation of detectors for TOF-PET

Abstract: Objective. Time-of-flight-positron emission tomography would highly benefit from a coincidence time resolution (CTR) below 100 ps: improvement in image quality and patient workflow, and reduction of delivered dose are among them. This achievement proved to be quite challenging, and many approaches have been proposed and are being investigated for this scope. One of the most recent consists in combining different materials with complementary properties (e.g. high stopping power for 511 keV … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
39
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 45 publications
(40 citation statements)
references
References 46 publications
1
39
0
Order By: Relevance
“…21 On the other hand, EJ232 was chosen as an ultra-fast plastic scintillator: it shows similar properties to the BC422 plastic scintillator (effective decay-time of ≈1.7 ns, rise time of ≈35 ps, intrinsic light yield of about 10 ph keV −1 21 ) but it can be produced in very thin layers with a better surface state. For the aforementioned reasons, EJ232 is one of the favorite materials in preliminary studies 27,28 about heterostructures.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…21 On the other hand, EJ232 was chosen as an ultra-fast plastic scintillator: it shows similar properties to the BC422 plastic scintillator (effective decay-time of ≈1.7 ns, rise time of ≈35 ps, intrinsic light yield of about 10 ph keV −1 21 ) but it can be produced in very thin layers with a better surface state. For the aforementioned reasons, EJ232 is one of the favorite materials in preliminary studies 27,28 about heterostructures.…”
Section: Resultsmentioning
confidence: 99%
“…The detector time resolution (DTR) – also known as single time resolution (STR), as opposed to coincidence time resolution (CTR) which takes into account a pair of detectors – was measured using a novel experimental setup with low energy X-ray irradiation developed purposely for the characterization of low-stopping power scintillators. 32,33 The setup includes a Hamamatsu pulsed X-ray tube, excited by a picosecond diode laser whose external trigger is used as the start signal for the DTR measurement. The stop signal instead is given by the output of the SiPM and is used for collecting the scintillation light emitted by the sample following the X-ray excitation.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Both works mention that the layers of the heterostructure should be smaller than the recoil range of the electrons to allow energy sharing between the two materials. In BGO, the average range of the primary electrons generated by 511 keV gamma rays is below 100 µm, whereas for LYSO it is slightly above 100 µm [24], [25].…”
Section: Introductionmentioning
confidence: 98%