2008
DOI: 10.1109/tns.2008.922819
|View full text |Cite
|
Sign up to set email alerts
|

Advances in Yield Calibration of Scintillators

Abstract: Abstract-By means of a photomultiplier tube, a Si-photodiode, and a Si-avalanche photodiode, the absolute scintillation yield of recently developed LaBr 3 :Ce, LaCl 3 :Ce, and (Lu Y) 2 SiO 5 :Ce scintillators and traditional Lu 2 SiO 5 :Ce, Bi 4 Ge 3 O 12 , NaI:Tl CsI:Tl, and CsI:Na scintillators were determined. These are all well known scintillators that cover emission wavelengths from 250 nm to 750 nm. By comparing the scintillation yield independently measured with the three different photon detectors reli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
102
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 186 publications
(105 citation statements)
references
References 16 publications
2
102
0
1
Order By: Relevance
“…The NaI:Tl assembly plus PMT entrance window was covered with several layers of ultraviolet reflecting Teflon tape ͑PFTE tape͒ forming an "umbrella" configuration. 21 Scintillation photons reflected from the photocathode are then reflected back by the umbrella thus enhancing detection efficiency. All measurements were carried out at room temperature and repeated several times.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The NaI:Tl assembly plus PMT entrance window was covered with several layers of ultraviolet reflecting Teflon tape ͑PFTE tape͒ forming an "umbrella" configuration. 21 Scintillation photons reflected from the photocathode are then reflected back by the umbrella thus enhancing detection efficiency. All measurements were carried out at room temperature and repeated several times.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Based on the photopeak positions, the numbers of photoelectrons released from the photocathode per 1 MeV of energy deposited in the crystal were calculated. Subsequently, the values of scintillation yield were estimated following the approach of de Haas and Dorenbos [10]. Representative samples of LuAG:Pr and LuYAG:Pr were also tested with an "enhanced" setup [11] equipped with a Hamamatsu R1791 PMT, which was more dedicated to gamma spectroscopy than R2059.…”
Section: Materials and Experimentsmentioning
confidence: 99%
“…The method and equipment used for avalanche photodiode (APD) readout was the same as reported in Ref. 8. An electronic shaping time of 2 ls was used.…”
Section: Co-dopingmentioning
confidence: 99%